双组分系统化学位移成像的选择性回波方法

Rex E. Gerald II, Anatoly O. Krasavin, Robert E. Botto
{"title":"双组分系统化学位移成像的选择性回波方法","authors":"Rex E. Gerald II,&nbsp;Anatoly O. Krasavin,&nbsp;Robert E. Botto","doi":"10.1006/jmra.1996.0236","DOIUrl":null,"url":null,"abstract":"<div><p>A simple and effective method for selectively imaging either one of two chemical species in a two-component system is presented and demonstrated experimentally. The pulse sequence employed,<em>s</em>elective-<em>e</em>cho<em>c</em>hemical-<em>s</em>hift<em>i</em>maging (SECSI), is a hybrid (frequency-selective/<em>T</em><sub>1</sub>-contrast) technique that is executed in a short period of time, utilizes the full Boltzmann magnetization of each chemical species to form the corresponding image, and requires only hard pulses of quadrature phase. This approach provides a direct and unambiguous representation of the spatial distribution of the two chemical species. In addition, the performance characteristics and the advantages of the SECSI sequence are compared on a common basis to those of other pulse sequences.</p></div>","PeriodicalId":16165,"journal":{"name":"Journal of Magnetic Resonance, Series A","volume":"123 2","pages":"Pages 201-206"},"PeriodicalIF":0.0000,"publicationDate":"1996-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1006/jmra.1996.0236","citationCount":"7","resultStr":"{\"title\":\"A Selective-Echo Method for Chemical-Shift Imaging of Two-Component Systems\",\"authors\":\"Rex E. Gerald II,&nbsp;Anatoly O. Krasavin,&nbsp;Robert E. Botto\",\"doi\":\"10.1006/jmra.1996.0236\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A simple and effective method for selectively imaging either one of two chemical species in a two-component system is presented and demonstrated experimentally. The pulse sequence employed,<em>s</em>elective-<em>e</em>cho<em>c</em>hemical-<em>s</em>hift<em>i</em>maging (SECSI), is a hybrid (frequency-selective/<em>T</em><sub>1</sub>-contrast) technique that is executed in a short period of time, utilizes the full Boltzmann magnetization of each chemical species to form the corresponding image, and requires only hard pulses of quadrature phase. This approach provides a direct and unambiguous representation of the spatial distribution of the two chemical species. In addition, the performance characteristics and the advantages of the SECSI sequence are compared on a common basis to those of other pulse sequences.</p></div>\",\"PeriodicalId\":16165,\"journal\":{\"name\":\"Journal of Magnetic Resonance, Series A\",\"volume\":\"123 2\",\"pages\":\"Pages 201-206\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1006/jmra.1996.0236\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance, Series A\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1064185896902363\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance, Series A","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1064185896902363","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文提出了一种简单而有效的方法,可以在双组分系统中选择性地成像两种化学物质中的任何一种。所采用的脉冲序列,选择性回声化学移位(SECSI),是一种混合(频率选择/ t1对比)技术,可以在短时间内执行,利用每种化学物质的全玻尔兹曼磁化来形成相应的图像,并且只需要正交相位的硬脉冲。这种方法提供了两种化学物质的空间分布的直接和明确的表示。在此基础上比较了SECSI序列与其他脉冲序列的性能特点和优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Selective-Echo Method for Chemical-Shift Imaging of Two-Component Systems

A simple and effective method for selectively imaging either one of two chemical species in a two-component system is presented and demonstrated experimentally. The pulse sequence employed,selective-echochemical-shiftimaging (SECSI), is a hybrid (frequency-selective/T1-contrast) technique that is executed in a short period of time, utilizes the full Boltzmann magnetization of each chemical species to form the corresponding image, and requires only hard pulses of quadrature phase. This approach provides a direct and unambiguous representation of the spatial distribution of the two chemical species. In addition, the performance characteristics and the advantages of the SECSI sequence are compared on a common basis to those of other pulse sequences.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信