分子筛吸附剂在空气净化过程中的非等温再生

V.A. Naumov, V.B. Vorotynthev, G.V. Kusiy
{"title":"分子筛吸附剂在空气净化过程中的非等温再生","authors":"V.A. Naumov,&nbsp;V.B. Vorotynthev,&nbsp;G.V. Kusiy","doi":"10.1016/0950-4214(94)80027-8","DOIUrl":null,"url":null,"abstract":"<div><p>Non-isothermal desorption of moisture and carbon dioxide from a layer of molecular sieve NaX has been studied on the basis of the proposed mathematical model. It is shown that it is not expedient to maintain the carbon dioxide desorption temperature above 353 K in the real industrial process while the minimum temperature of the moisture desorption should be within the range 373–423 K. The application of the thermal wave adsorption method to the problem of regeneration from the main impurities of air allows the power consumption to be significantly reduced. A simplified model of a cyclic process of air purification under incomplete desorption of moisture has been suggested. A comparison is made of the results of the calculations and the test data obtained on the commercial adsorbers of a low-pressure air separation plant when the regenerating gas temperature is decreased from 653 to 373 K. Good qualitative and satisfactory quantitative agreement of the calculated and observed results is observed.</p></div>","PeriodicalId":12586,"journal":{"name":"Gas Separation & Purification","volume":"8 3","pages":"Pages 167-174"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0950-4214(94)80027-8","citationCount":"1","resultStr":"{\"title\":\"Non-isothermal regeneration of molecular sieve adsorbers in a cyclic process of air purification from moisture and carbon dioxide\",\"authors\":\"V.A. Naumov,&nbsp;V.B. Vorotynthev,&nbsp;G.V. Kusiy\",\"doi\":\"10.1016/0950-4214(94)80027-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Non-isothermal desorption of moisture and carbon dioxide from a layer of molecular sieve NaX has been studied on the basis of the proposed mathematical model. It is shown that it is not expedient to maintain the carbon dioxide desorption temperature above 353 K in the real industrial process while the minimum temperature of the moisture desorption should be within the range 373–423 K. The application of the thermal wave adsorption method to the problem of regeneration from the main impurities of air allows the power consumption to be significantly reduced. A simplified model of a cyclic process of air purification under incomplete desorption of moisture has been suggested. A comparison is made of the results of the calculations and the test data obtained on the commercial adsorbers of a low-pressure air separation plant when the regenerating gas temperature is decreased from 653 to 373 K. Good qualitative and satisfactory quantitative agreement of the calculated and observed results is observed.</p></div>\",\"PeriodicalId\":12586,\"journal\":{\"name\":\"Gas Separation & Purification\",\"volume\":\"8 3\",\"pages\":\"Pages 167-174\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0950-4214(94)80027-8\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gas Separation & Purification\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0950421494800278\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gas Separation & Purification","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0950421494800278","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

根据所建立的数学模型,研究了NaX分子筛层中水分和二氧化碳的非等温解吸。结果表明,在实际工业过程中,二氧化碳解吸温度不宜保持在353 K以上,而水分解吸的最低温度应在373 ~ 423 K之间。将热波吸附法应用于空气中主要杂质的再生问题,使能耗显著降低。提出了不完全解吸条件下空气净化循环过程的简化模型。将再生气温度从653 K降至373 K时的计算结果与某低压空分装置工业吸附器的试验数据进行了比较。计算结果与观测结果在定性和定量上都很吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Non-isothermal regeneration of molecular sieve adsorbers in a cyclic process of air purification from moisture and carbon dioxide

Non-isothermal desorption of moisture and carbon dioxide from a layer of molecular sieve NaX has been studied on the basis of the proposed mathematical model. It is shown that it is not expedient to maintain the carbon dioxide desorption temperature above 353 K in the real industrial process while the minimum temperature of the moisture desorption should be within the range 373–423 K. The application of the thermal wave adsorption method to the problem of regeneration from the main impurities of air allows the power consumption to be significantly reduced. A simplified model of a cyclic process of air purification under incomplete desorption of moisture has been suggested. A comparison is made of the results of the calculations and the test data obtained on the commercial adsorbers of a low-pressure air separation plant when the regenerating gas temperature is decreased from 653 to 373 K. Good qualitative and satisfactory quantitative agreement of the calculated and observed results is observed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信