A. Baschirotto, E. Dallago, P. Malcovati, M. Marchesi, G. Venchi
{"title":"电子罗盘高精度矢量二维磁场传感器系统","authors":"A. Baschirotto, E. Dallago, P. Malcovati, M. Marchesi, G. Venchi","doi":"10.1109/ICSENS.2004.1426349","DOIUrl":null,"url":null,"abstract":"An high sensitivity vector-2D magnetic sensor system for low magnetic field measurements has been realized and tested. The system, realized in PCB technology, consists of a double axis fluxgate magnetic sensor with its front-end electronic circuitry based on second-harmonic detection. The amorphous magnetic materials Vitrovac 6025X (25 /spl mu/m thick) and Vitrovac 6025Z (20 /spl mu/m thick) were used as a ferromagnetic core for the sensor. Applying a sinusoidal excitation current of 450 mA peak at 10 kHz with the Vitrovac 6025Z, the magnetic sensitivity was about 1.25 mV//spl mu/T, suitable for detecting the Earth's magnetic field (/spl plusmn/60 /spl mu/T), while the linearity error is 1.5% full scale. Using the thicker Vitrovac 6025X, a maximum sensitivity of about 1.68 mV//spl mu/T and a linearity error of about 1.55% full scale in the range of /spl plusmn/60 /spl mu/T were obtained with a larger sinusoidal excitation current of 600 mA peak at 10 kHz. The 2D vector sensor system presented is characterized by a very simple process fabrication due to the use of commercially available very thin ferromagnetic material.","PeriodicalId":20476,"journal":{"name":"Proceedings of IEEE Sensors, 2004.","volume":"95 1","pages":"1028-1031 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Precise vector-2D magnetic field sensor system for electronic compass\",\"authors\":\"A. Baschirotto, E. Dallago, P. Malcovati, M. Marchesi, G. Venchi\",\"doi\":\"10.1109/ICSENS.2004.1426349\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An high sensitivity vector-2D magnetic sensor system for low magnetic field measurements has been realized and tested. The system, realized in PCB technology, consists of a double axis fluxgate magnetic sensor with its front-end electronic circuitry based on second-harmonic detection. The amorphous magnetic materials Vitrovac 6025X (25 /spl mu/m thick) and Vitrovac 6025Z (20 /spl mu/m thick) were used as a ferromagnetic core for the sensor. Applying a sinusoidal excitation current of 450 mA peak at 10 kHz with the Vitrovac 6025Z, the magnetic sensitivity was about 1.25 mV//spl mu/T, suitable for detecting the Earth's magnetic field (/spl plusmn/60 /spl mu/T), while the linearity error is 1.5% full scale. Using the thicker Vitrovac 6025X, a maximum sensitivity of about 1.68 mV//spl mu/T and a linearity error of about 1.55% full scale in the range of /spl plusmn/60 /spl mu/T were obtained with a larger sinusoidal excitation current of 600 mA peak at 10 kHz. The 2D vector sensor system presented is characterized by a very simple process fabrication due to the use of commercially available very thin ferromagnetic material.\",\"PeriodicalId\":20476,\"journal\":{\"name\":\"Proceedings of IEEE Sensors, 2004.\",\"volume\":\"95 1\",\"pages\":\"1028-1031 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE Sensors, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2004.1426349\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Sensors, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2004.1426349","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Precise vector-2D magnetic field sensor system for electronic compass
An high sensitivity vector-2D magnetic sensor system for low magnetic field measurements has been realized and tested. The system, realized in PCB technology, consists of a double axis fluxgate magnetic sensor with its front-end electronic circuitry based on second-harmonic detection. The amorphous magnetic materials Vitrovac 6025X (25 /spl mu/m thick) and Vitrovac 6025Z (20 /spl mu/m thick) were used as a ferromagnetic core for the sensor. Applying a sinusoidal excitation current of 450 mA peak at 10 kHz with the Vitrovac 6025Z, the magnetic sensitivity was about 1.25 mV//spl mu/T, suitable for detecting the Earth's magnetic field (/spl plusmn/60 /spl mu/T), while the linearity error is 1.5% full scale. Using the thicker Vitrovac 6025X, a maximum sensitivity of about 1.68 mV//spl mu/T and a linearity error of about 1.55% full scale in the range of /spl plusmn/60 /spl mu/T were obtained with a larger sinusoidal excitation current of 600 mA peak at 10 kHz. The 2D vector sensor system presented is characterized by a very simple process fabrication due to the use of commercially available very thin ferromagnetic material.