湿老化对交联聚乙烯电缆片电击穿强度的影响

C. Chauvet, C. Laurent, C. Mayoux
{"title":"湿老化对交联聚乙烯电缆片电击穿强度的影响","authors":"C. Chauvet, C. Laurent, C. Mayoux","doi":"10.1109/CEIDP.1989.69551","DOIUrl":null,"url":null,"abstract":"In order to investigate the consequences of water-induced degradation on the dielectric breakdown field of polyethylene, the authors performed statistical electric breakdown strength measurements on cable slices previously aged in the presence of water. A Weibull analysis is performed on at least 40 sets of breakdown voltage data for each population, leading to a precise determination of the nominal breakdown field E/sub 0/. Comparison is made as a function of ageing time and testing conditions. Wet ageing under conditions of water tree development affects the breakdown strength of XLPE (cross-linked polyethylene) cable slices. The presence of water trees in the insulation must therefore be considered as potentially harmful.<<ETX>>","PeriodicalId":10719,"journal":{"name":"Conference on Electrical Insulation and Dielectric Phenomena,","volume":"100 1","pages":"230-234"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Influence of wet ageing on the electrical breakdown strength of XLPE cable slices\",\"authors\":\"C. Chauvet, C. Laurent, C. Mayoux\",\"doi\":\"10.1109/CEIDP.1989.69551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to investigate the consequences of water-induced degradation on the dielectric breakdown field of polyethylene, the authors performed statistical electric breakdown strength measurements on cable slices previously aged in the presence of water. A Weibull analysis is performed on at least 40 sets of breakdown voltage data for each population, leading to a precise determination of the nominal breakdown field E/sub 0/. Comparison is made as a function of ageing time and testing conditions. Wet ageing under conditions of water tree development affects the breakdown strength of XLPE (cross-linked polyethylene) cable slices. The presence of water trees in the insulation must therefore be considered as potentially harmful.<<ETX>>\",\"PeriodicalId\":10719,\"journal\":{\"name\":\"Conference on Electrical Insulation and Dielectric Phenomena,\",\"volume\":\"100 1\",\"pages\":\"230-234\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference on Electrical Insulation and Dielectric Phenomena,\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1989.69551\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1989.69551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

为了研究水诱导降解对聚乙烯介电击穿场的影响,作者对先前在存在水的情况下老化的电缆片进行了统计电击穿强度测量。威布尔分析对每个群体至少40组击穿电压数据进行了分析,从而精确确定了标称击穿场E/sub 0/。比较了老化时间和试验条件的函数关系。水树发育条件下的湿老化影响交联聚乙烯电缆片的击穿强度。因此,绝缘材料中存在的水柱必须被认为是潜在的有害物质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of wet ageing on the electrical breakdown strength of XLPE cable slices
In order to investigate the consequences of water-induced degradation on the dielectric breakdown field of polyethylene, the authors performed statistical electric breakdown strength measurements on cable slices previously aged in the presence of water. A Weibull analysis is performed on at least 40 sets of breakdown voltage data for each population, leading to a precise determination of the nominal breakdown field E/sub 0/. Comparison is made as a function of ageing time and testing conditions. Wet ageing under conditions of water tree development affects the breakdown strength of XLPE (cross-linked polyethylene) cable slices. The presence of water trees in the insulation must therefore be considered as potentially harmful.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信