{"title":"引脚受限数字微流控生物芯片面向可靠性的广播电极寻址","authors":"Tsung-Wei Huang, Tsung-Yi Ho, K. Chakrabarty","doi":"10.1109/ICCAD.2011.6105367","DOIUrl":null,"url":null,"abstract":"Designs for pin-constrained digital microfluidic biochips (PDMFBs) are receiving much attention because they simplify chip fabrication and packaging, and reduce product cost. To reduce the pin count, broadcast addressing, by minimally grouping electrode sets with non-conflict signal merging, has emerged as a promising solution. Nevertheless, naive signal merging has the potential to cause excessive electrode actuations, which has been reported to have direct and adverse effect on chip reliability. According to recent studies, reliability is an important attribute for PDMFBs particularly developed for medical applications as it directly affects the final medical decision making. However, no research findings have been reported on the reliability problem in pin-constrained designs. To make PDMFBs more feasible for practical applications, we propose in this paper the first matching-based reliability-oriented broadcast-addressing algorithm for PDMFBs. We identify the factors that affect reliability and incorporate into the design-technique attributes that enhance reliability. Experimental results demonstrate the effectiveness of the proposed algorithm.","PeriodicalId":6357,"journal":{"name":"2011 IEEE/ACM International Conference on Computer-Aided Design (ICCAD)","volume":"4 1","pages":"448-455"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"47","resultStr":"{\"title\":\"Reliability-oriented broadcast electrode-addressing for pin-constrained digital microfluidic biochips\",\"authors\":\"Tsung-Wei Huang, Tsung-Yi Ho, K. Chakrabarty\",\"doi\":\"10.1109/ICCAD.2011.6105367\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Designs for pin-constrained digital microfluidic biochips (PDMFBs) are receiving much attention because they simplify chip fabrication and packaging, and reduce product cost. To reduce the pin count, broadcast addressing, by minimally grouping electrode sets with non-conflict signal merging, has emerged as a promising solution. Nevertheless, naive signal merging has the potential to cause excessive electrode actuations, which has been reported to have direct and adverse effect on chip reliability. According to recent studies, reliability is an important attribute for PDMFBs particularly developed for medical applications as it directly affects the final medical decision making. However, no research findings have been reported on the reliability problem in pin-constrained designs. To make PDMFBs more feasible for practical applications, we propose in this paper the first matching-based reliability-oriented broadcast-addressing algorithm for PDMFBs. We identify the factors that affect reliability and incorporate into the design-technique attributes that enhance reliability. Experimental results demonstrate the effectiveness of the proposed algorithm.\",\"PeriodicalId\":6357,\"journal\":{\"name\":\"2011 IEEE/ACM International Conference on Computer-Aided Design (ICCAD)\",\"volume\":\"4 1\",\"pages\":\"448-455\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"47\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE/ACM International Conference on Computer-Aided Design (ICCAD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCAD.2011.6105367\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE/ACM International Conference on Computer-Aided Design (ICCAD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCAD.2011.6105367","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reliability-oriented broadcast electrode-addressing for pin-constrained digital microfluidic biochips
Designs for pin-constrained digital microfluidic biochips (PDMFBs) are receiving much attention because they simplify chip fabrication and packaging, and reduce product cost. To reduce the pin count, broadcast addressing, by minimally grouping electrode sets with non-conflict signal merging, has emerged as a promising solution. Nevertheless, naive signal merging has the potential to cause excessive electrode actuations, which has been reported to have direct and adverse effect on chip reliability. According to recent studies, reliability is an important attribute for PDMFBs particularly developed for medical applications as it directly affects the final medical decision making. However, no research findings have been reported on the reliability problem in pin-constrained designs. To make PDMFBs more feasible for practical applications, we propose in this paper the first matching-based reliability-oriented broadcast-addressing algorithm for PDMFBs. We identify the factors that affect reliability and incorporate into the design-technique attributes that enhance reliability. Experimental results demonstrate the effectiveness of the proposed algorithm.