实验中3d打印植入物的组织学检查及生物相容性评价。

D. Kuliesh, N. Galatenko, R. Rozhnova, V. Gritsenko, A. Bogdan, V. B. Volkov
{"title":"实验中3d打印植入物的组织学检查及生物相容性评价。","authors":"D. Kuliesh, N. Galatenko, R. Rozhnova, V. Gritsenko, A. Bogdan, V. B. Volkov","doi":"10.26641/1997-9665.2020.1.35-41","DOIUrl":null,"url":null,"abstract":"Background. High levels of musculoskeletal injuries, pathologies and various diseases of bone tissue encourage researchers around the world to actively seek out new and improve existing implant materials for high-quality reconstructive and restorative operations on bone tissue. Objective. Histological examination and evaluation of biocompatibility of 3-D printed implants after implantation in experimental animals. Methods. 3-D printed materials were implanted into the white laboratory rats Wistar for 1, 4, and 12 weeks. The cellular reactions of the organism and possible changes in the structure of the test specimens after implantation were studied by light microscopy by histological micropreparation analysis. Results. Histological examination was performed and the nature and dynamics of cellular responses after implantation of 3-D printed materials were evaluated. Conclusion. It was found that cellular migration and germination of connective tissue tendons deep into the implants due to the porous structure of 3-D printed material based on ceramics, resulted in partial degradation, which slightly increased the intensity of cellular reactions at all study periods. It was found that the intensity of cellular reactions was minimal in the early stages of the study around polymer-based 3-D printed material, but 12 weeks after implantation, cellular responses were increased. It is shown that implantation of 3-D printed materials into the body of experimental animals led to the development of cellular responses typical of aseptic inflammation, which testified to their biocompatibility.","PeriodicalId":19107,"journal":{"name":"Morphologia","volume":"46 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Histological examination and evaluation of biocompatibility of 3-D printed implants in the experiment.\",\"authors\":\"D. Kuliesh, N. Galatenko, R. Rozhnova, V. Gritsenko, A. Bogdan, V. B. Volkov\",\"doi\":\"10.26641/1997-9665.2020.1.35-41\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background. High levels of musculoskeletal injuries, pathologies and various diseases of bone tissue encourage researchers around the world to actively seek out new and improve existing implant materials for high-quality reconstructive and restorative operations on bone tissue. Objective. Histological examination and evaluation of biocompatibility of 3-D printed implants after implantation in experimental animals. Methods. 3-D printed materials were implanted into the white laboratory rats Wistar for 1, 4, and 12 weeks. The cellular reactions of the organism and possible changes in the structure of the test specimens after implantation were studied by light microscopy by histological micropreparation analysis. Results. Histological examination was performed and the nature and dynamics of cellular responses after implantation of 3-D printed materials were evaluated. Conclusion. It was found that cellular migration and germination of connective tissue tendons deep into the implants due to the porous structure of 3-D printed material based on ceramics, resulted in partial degradation, which slightly increased the intensity of cellular reactions at all study periods. It was found that the intensity of cellular reactions was minimal in the early stages of the study around polymer-based 3-D printed material, but 12 weeks after implantation, cellular responses were increased. It is shown that implantation of 3-D printed materials into the body of experimental animals led to the development of cellular responses typical of aseptic inflammation, which testified to their biocompatibility.\",\"PeriodicalId\":19107,\"journal\":{\"name\":\"Morphologia\",\"volume\":\"46 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Morphologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26641/1997-9665.2020.1.35-41\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Morphologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26641/1997-9665.2020.1.35-41","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Histological examination and evaluation of biocompatibility of 3-D printed implants in the experiment.
Background. High levels of musculoskeletal injuries, pathologies and various diseases of bone tissue encourage researchers around the world to actively seek out new and improve existing implant materials for high-quality reconstructive and restorative operations on bone tissue. Objective. Histological examination and evaluation of biocompatibility of 3-D printed implants after implantation in experimental animals. Methods. 3-D printed materials were implanted into the white laboratory rats Wistar for 1, 4, and 12 weeks. The cellular reactions of the organism and possible changes in the structure of the test specimens after implantation were studied by light microscopy by histological micropreparation analysis. Results. Histological examination was performed and the nature and dynamics of cellular responses after implantation of 3-D printed materials were evaluated. Conclusion. It was found that cellular migration and germination of connective tissue tendons deep into the implants due to the porous structure of 3-D printed material based on ceramics, resulted in partial degradation, which slightly increased the intensity of cellular reactions at all study periods. It was found that the intensity of cellular reactions was minimal in the early stages of the study around polymer-based 3-D printed material, but 12 weeks after implantation, cellular responses were increased. It is shown that implantation of 3-D printed materials into the body of experimental animals led to the development of cellular responses typical of aseptic inflammation, which testified to their biocompatibility.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信