{"title":"考虑固有不平衡和静偏心的DFIG转子匝间短路故障特征","authors":"Junqing Li, Lipeng Zhang, W. Shi","doi":"10.1109/ECCE.2015.7309793","DOIUrl":null,"url":null,"abstract":"The performance of doubly-fed induction generators (DFIGs) would be affected by the rotor winding inter-turn short circuit fault, such as harmonics increase in electromagnetic quantities and torque pulsation. Thus, it is necessary to monitor and diagnose the rotor inter-turn fault for DFIGs. However, the rotor three-phase windings inherent imbalance and static air gap eccentricity may cause misdiagnosis of the rotor winding inter-turn fault. The finite element models of the DFIG are presented firstly, which consider the rotor three-phase windings inherent imbalance and static air gap eccentricity respectively. Then the rotor inter-turn short circuit faults of DFIGs are simulated under both conditions. Based on the characteristics analysis of the stator line voltage, rotor line current and electromagnetic torque from the simulation, a diagnosis method for the DFIG rotor inter-turn fault is proposed, which could avoid misdiagnosis caused by the rotor three-phase winding inherent imbalance and static air gap eccentricity and increase the diagnosis accuracy.","PeriodicalId":6654,"journal":{"name":"2015 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"21 1","pages":"971-975"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fault characteristics of the DFIG rotor inter-turn short circuit considering inherent imbalance and static eccentricity\",\"authors\":\"Junqing Li, Lipeng Zhang, W. Shi\",\"doi\":\"10.1109/ECCE.2015.7309793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of doubly-fed induction generators (DFIGs) would be affected by the rotor winding inter-turn short circuit fault, such as harmonics increase in electromagnetic quantities and torque pulsation. Thus, it is necessary to monitor and diagnose the rotor inter-turn fault for DFIGs. However, the rotor three-phase windings inherent imbalance and static air gap eccentricity may cause misdiagnosis of the rotor winding inter-turn fault. The finite element models of the DFIG are presented firstly, which consider the rotor three-phase windings inherent imbalance and static air gap eccentricity respectively. Then the rotor inter-turn short circuit faults of DFIGs are simulated under both conditions. Based on the characteristics analysis of the stator line voltage, rotor line current and electromagnetic torque from the simulation, a diagnosis method for the DFIG rotor inter-turn fault is proposed, which could avoid misdiagnosis caused by the rotor three-phase winding inherent imbalance and static air gap eccentricity and increase the diagnosis accuracy.\",\"PeriodicalId\":6654,\"journal\":{\"name\":\"2015 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"volume\":\"21 1\",\"pages\":\"971-975\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE.2015.7309793\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2015.7309793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fault characteristics of the DFIG rotor inter-turn short circuit considering inherent imbalance and static eccentricity
The performance of doubly-fed induction generators (DFIGs) would be affected by the rotor winding inter-turn short circuit fault, such as harmonics increase in electromagnetic quantities and torque pulsation. Thus, it is necessary to monitor and diagnose the rotor inter-turn fault for DFIGs. However, the rotor three-phase windings inherent imbalance and static air gap eccentricity may cause misdiagnosis of the rotor winding inter-turn fault. The finite element models of the DFIG are presented firstly, which consider the rotor three-phase windings inherent imbalance and static air gap eccentricity respectively. Then the rotor inter-turn short circuit faults of DFIGs are simulated under both conditions. Based on the characteristics analysis of the stator line voltage, rotor line current and electromagnetic torque from the simulation, a diagnosis method for the DFIG rotor inter-turn fault is proposed, which could avoid misdiagnosis caused by the rotor three-phase winding inherent imbalance and static air gap eccentricity and increase the diagnosis accuracy.