Nurulilyana Sansuddin, Siti Mariam Nordin
{"title":"USM健康校区图书馆不同楼层PM10和PM2.5浓度评估","authors":"Nurulilyana Sansuddin, Siti Mariam Nordin","doi":"10.11113/jest.v5n1.105","DOIUrl":null,"url":null,"abstract":"Library plays an important role in education and research materials especially used by university students. And it is known that university students prefer to spend most of their time in the library. There are multifactorial of high concentration of pollutants in a building, thus library is the best choice in this study to prove it. The purpose of this study is to assess the indoor air quality (IAQ) in library at USM Health Campus, Kota Bharu, Kelantan. The comparison of PM10 and PM2.5 concentrations between different floor levels of library was determined. This study was also conducted to obtain the relation between PM10 and PM2.5 concentrations with the number of occupants, temperature, relative humidity and total number of books. Particulate matter concentrations were measured at library by using Handheld 3016 IAQ Particle Counter. The data was collected for eight hours for each floor with five minutes time interval. Based on Kruskal Wallis test, there were significant differences of PM2.5 and PM10 concentrations between floor levels (p<0.05). Number of occupants was found significant to PM2.5 concentrations through Spearman Correlation test (p<0.05). Furthermore, two of environmental factors (temperature and relative humidity) were found poorly significant with PM10 and PM2.5 concentrations which r-value were less than 0.3 (r-PM10=0.22, r-PM2.5=-0.15; r-PM10=-0.17, r-PM2.5=0.2). Number of books and different floor surface area of library were obtained as contributing factor which increased PM concentration. In conclusion, cleaning and housekeeping activities in library need to regularly practice to minimize IAQ problems in order to provide a healthier indoor environment.","PeriodicalId":15706,"journal":{"name":"Journal of Energy and Safety Technology (JEST)","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of PM10 and PM2.5 Concentrations at Different Floor Levels of USM Health Campus’s Library\",\"authors\":\"Nurulilyana Sansuddin, Siti Mariam Nordin\",\"doi\":\"10.11113/jest.v5n1.105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Library plays an important role in education and research materials especially used by university students. And it is known that university students prefer to spend most of their time in the library. There are multifactorial of high concentration of pollutants in a building, thus library is the best choice in this study to prove it. The purpose of this study is to assess the indoor air quality (IAQ) in library at USM Health Campus, Kota Bharu, Kelantan. The comparison of PM10 and PM2.5 concentrations between different floor levels of library was determined. This study was also conducted to obtain the relation between PM10 and PM2.5 concentrations with the number of occupants, temperature, relative humidity and total number of books. Particulate matter concentrations were measured at library by using Handheld 3016 IAQ Particle Counter. The data was collected for eight hours for each floor with five minutes time interval. Based on Kruskal Wallis test, there were significant differences of PM2.5 and PM10 concentrations between floor levels (p<0.05). Number of occupants was found significant to PM2.5 concentrations through Spearman Correlation test (p<0.05). Furthermore, two of environmental factors (temperature and relative humidity) were found poorly significant with PM10 and PM2.5 concentrations which r-value were less than 0.3 (r-PM10=0.22, r-PM2.5=-0.15; r-PM10=-0.17, r-PM2.5=0.2). Number of books and different floor surface area of library were obtained as contributing factor which increased PM concentration. In conclusion, cleaning and housekeeping activities in library need to regularly practice to minimize IAQ problems in order to provide a healthier indoor environment.\",\"PeriodicalId\":15706,\"journal\":{\"name\":\"Journal of Energy and Safety Technology (JEST)\",\"volume\":\"22 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Energy and Safety Technology (JEST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11113/jest.v5n1.105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Energy and Safety Technology (JEST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11113/jest.v5n1.105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

图书馆在教育和研究方面发挥着重要作用,尤其是大学生所使用的资料。众所周知,大学生更喜欢把大部分时间花在图书馆。建筑中存在高浓度污染物的多因素影响,因此图书馆是本研究的最佳选择。本研究的目的是评估吉兰丹州哥打巴鲁USM健康校区图书馆的室内空气质量。对图书馆不同楼层的PM10和PM2.5浓度进行比较。本研究还获得了PM10和PM2.5浓度与居住人数、温度、相对湿度和图书总量的关系。采用手持式3016室内空气质量粒子计数器在图书馆测量颗粒物浓度。每层楼的数据收集时间为8小时,每隔5分钟。根据Kruskal Wallis检验,PM2.5和PM10浓度在不同楼层之间存在显著差异(p<0.05)。Spearman相关检验发现,居住人数对PM2.5浓度有显著影响(p<0.05)。此外,当PM10和PM2.5浓度r值小于0.3时,温度和相对湿度这两个环境因子不显著(r-PM10=0.22, r-PM2.5=-0.15;r-PM10 = -0.17, r-PM2.5 = 0.2)。图书数量和图书馆不同的建筑面积是影响PM浓度的因素。总之,图书馆的清洁和清洁活动需要定期练习,以尽量减少室内空气质量问题,以提供一个更健康的室内环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of PM10 and PM2.5 Concentrations at Different Floor Levels of USM Health Campus’s Library
Library plays an important role in education and research materials especially used by university students. And it is known that university students prefer to spend most of their time in the library. There are multifactorial of high concentration of pollutants in a building, thus library is the best choice in this study to prove it. The purpose of this study is to assess the indoor air quality (IAQ) in library at USM Health Campus, Kota Bharu, Kelantan. The comparison of PM10 and PM2.5 concentrations between different floor levels of library was determined. This study was also conducted to obtain the relation between PM10 and PM2.5 concentrations with the number of occupants, temperature, relative humidity and total number of books. Particulate matter concentrations were measured at library by using Handheld 3016 IAQ Particle Counter. The data was collected for eight hours for each floor with five minutes time interval. Based on Kruskal Wallis test, there were significant differences of PM2.5 and PM10 concentrations between floor levels (p<0.05). Number of occupants was found significant to PM2.5 concentrations through Spearman Correlation test (p<0.05). Furthermore, two of environmental factors (temperature and relative humidity) were found poorly significant with PM10 and PM2.5 concentrations which r-value were less than 0.3 (r-PM10=0.22, r-PM2.5=-0.15; r-PM10=-0.17, r-PM2.5=0.2). Number of books and different floor surface area of library were obtained as contributing factor which increased PM concentration. In conclusion, cleaning and housekeeping activities in library need to regularly practice to minimize IAQ problems in order to provide a healthier indoor environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信