{"title":"基于洛伦兹力振幅的磁声层析成像重建方法","authors":"Jin Liu, Liang Mao, Dakun Lai, Guoqiang Liu","doi":"10.1109/ICISCE.2016.29","DOIUrl":null,"url":null,"abstract":"Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging electrical impedance properties of biological tissue, which integrates classic electrical impedance tomography and ultrasonic technique. Image reconstruction is the key problem of MAT-MI. At present, there are certain problems for the image reconstruction methods which based on the divergence of Lorentz force. In this work, a novel reconstruction method based on the amplitude of Lorentz force instead of its divergence is proposed to avoid the singularity of the divergence of Lorentz force on the interface between two kinds of medium. Meanwhile, a two dimensional complex model was built, and preliminarily numerical simulations were carried out to evaluate the proposed method. With the rhetorical analysis and computational results, the proposed straightforward method for imaging electrical impedance properties would potentially be implemented more accurately for the MAT-MI system.","PeriodicalId":6882,"journal":{"name":"2016 3rd International Conference on Information Science and Control Engineering (ICISCE)","volume":"155 1","pages":"88-90"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Reconstruction Method of Magnetoacoustic Tomography with Magnetic Induction Based on the Amplitude of Lorentz Force\",\"authors\":\"Jin Liu, Liang Mao, Dakun Lai, Guoqiang Liu\",\"doi\":\"10.1109/ICISCE.2016.29\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging electrical impedance properties of biological tissue, which integrates classic electrical impedance tomography and ultrasonic technique. Image reconstruction is the key problem of MAT-MI. At present, there are certain problems for the image reconstruction methods which based on the divergence of Lorentz force. In this work, a novel reconstruction method based on the amplitude of Lorentz force instead of its divergence is proposed to avoid the singularity of the divergence of Lorentz force on the interface between two kinds of medium. Meanwhile, a two dimensional complex model was built, and preliminarily numerical simulations were carried out to evaluate the proposed method. With the rhetorical analysis and computational results, the proposed straightforward method for imaging electrical impedance properties would potentially be implemented more accurately for the MAT-MI system.\",\"PeriodicalId\":6882,\"journal\":{\"name\":\"2016 3rd International Conference on Information Science and Control Engineering (ICISCE)\",\"volume\":\"155 1\",\"pages\":\"88-90\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 3rd International Conference on Information Science and Control Engineering (ICISCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICISCE.2016.29\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 3rd International Conference on Information Science and Control Engineering (ICISCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISCE.2016.29","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Novel Reconstruction Method of Magnetoacoustic Tomography with Magnetic Induction Based on the Amplitude of Lorentz Force
Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging electrical impedance properties of biological tissue, which integrates classic electrical impedance tomography and ultrasonic technique. Image reconstruction is the key problem of MAT-MI. At present, there are certain problems for the image reconstruction methods which based on the divergence of Lorentz force. In this work, a novel reconstruction method based on the amplitude of Lorentz force instead of its divergence is proposed to avoid the singularity of the divergence of Lorentz force on the interface between two kinds of medium. Meanwhile, a two dimensional complex model was built, and preliminarily numerical simulations were carried out to evaluate the proposed method. With the rhetorical analysis and computational results, the proposed straightforward method for imaging electrical impedance properties would potentially be implemented more accurately for the MAT-MI system.