M. C. Yebra, N. Carro, A. Moreno-Cid, L. Puig
{"title":"小柱现场取样-流动注射-原子吸收光谱法测定海水中铅","authors":"M. C. Yebra, N. Carro, A. Moreno-Cid, L. Puig","doi":"10.1002/fact.10003","DOIUrl":null,"url":null,"abstract":"<p>A simple field-flow preconcentration system has been developed for lead determination in seawater. Seawater samples are collected in situ by passing them with a pump through minicolumns packed with poly(aminophosphonic acid) chelating resin to retain and preconcentrate lead, and remove the saline matrix. Minicolumns loaded with lead are then returned to the laboratory where they are inserted into a flow-injection system and eluted with a small volume of hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. The detection limit for lead in seawater was 2.8 ng l<sup>−1</sup>. This procedure was applied to the determination of lead in seawater samples from Galicia (Spain). © 2001 John Wiley & Sons, Inc. Field Analyt Chem Technol 5: 239–243, 2001</p>","PeriodicalId":100527,"journal":{"name":"Field Analytical Chemistry & Technology","volume":"5 5","pages":"239-243"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/fact.10003","citationCount":"7","resultStr":"{\"title\":\"Minicolumn field sampling and flow-injection-atomic absorption spectrometric determination of lead in seawater\",\"authors\":\"M. C. Yebra, N. Carro, A. Moreno-Cid, L. Puig\",\"doi\":\"10.1002/fact.10003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A simple field-flow preconcentration system has been developed for lead determination in seawater. Seawater samples are collected in situ by passing them with a pump through minicolumns packed with poly(aminophosphonic acid) chelating resin to retain and preconcentrate lead, and remove the saline matrix. Minicolumns loaded with lead are then returned to the laboratory where they are inserted into a flow-injection system and eluted with a small volume of hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. The detection limit for lead in seawater was 2.8 ng l<sup>−1</sup>. This procedure was applied to the determination of lead in seawater samples from Galicia (Spain). © 2001 John Wiley & Sons, Inc. Field Analyt Chem Technol 5: 239–243, 2001</p>\",\"PeriodicalId\":100527,\"journal\":{\"name\":\"Field Analytical Chemistry & Technology\",\"volume\":\"5 5\",\"pages\":\"239-243\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/fact.10003\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Field Analytical Chemistry & Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/fact.10003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry & Technology","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/fact.10003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7