用光栅立体技术测量物体和主体的圆柱体形状和曲率的实验装置的校准和验证

M. Ahmed, S. S. Zaidi
{"title":"用光栅立体技术测量物体和主体的圆柱体形状和曲率的实验装置的校准和验证","authors":"M. Ahmed, S. S. Zaidi","doi":"10.22581/muet1982.1901.16","DOIUrl":null,"url":null,"abstract":"The intent of study is to establish a criterion for the experimental setup of rasterstereography, one that is more efficient, simple, accurate and precise to examine and analyse the curvature of the object or the subject. Firstly, the setup is needed to be calibrated and for this purpose we considered a reference plane, eleven cylinders of different diameter ranging from 30-119mm were used for calibration of curvature maps of cylinders and cylindrical objects through the regression line. Further this model was tested on subjects and for that we reckoned cylindrical body parts of boys and a total of 30 college students were involved as subjects in this process. The body parts to be measured had curvature like cylinders of different diameters ranging from 42-120mm. The distortion of raster grid was observed, quantified and recorded with the help of different tools and results were established. The regression line was obtained between the measured (x) and computed (y). The standard error of the cylindrical object was 0..04 and that of cylindrical body parts of subjects was 0.0407. This technique was validated through the coefficient of correlation for objects and subjects which was found to be 0.99982 and 0.999141 respectively. Accuracy and Precision were also calculated for this model, which were 99.60% accurate and 99.49% precise. Curvature maps were found more than 99%. This technique is inexpensive, reliable, reproducible and may be installed easily in hospitals to examine appraise body shape, composition and deformities of young men.","PeriodicalId":13063,"journal":{"name":"Hygeia J. D.Med.10 (1) August 2018 - January 2019","volume":"35 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Calibration and Validation of an Experimental Setup for the Measurement of the Cylindrical Body Shapes and Curvatures of the Objects and Subjects through the Techniques of Rasterstereography\",\"authors\":\"M. Ahmed, S. S. Zaidi\",\"doi\":\"10.22581/muet1982.1901.16\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The intent of study is to establish a criterion for the experimental setup of rasterstereography, one that is more efficient, simple, accurate and precise to examine and analyse the curvature of the object or the subject. Firstly, the setup is needed to be calibrated and for this purpose we considered a reference plane, eleven cylinders of different diameter ranging from 30-119mm were used for calibration of curvature maps of cylinders and cylindrical objects through the regression line. Further this model was tested on subjects and for that we reckoned cylindrical body parts of boys and a total of 30 college students were involved as subjects in this process. The body parts to be measured had curvature like cylinders of different diameters ranging from 42-120mm. The distortion of raster grid was observed, quantified and recorded with the help of different tools and results were established. The regression line was obtained between the measured (x) and computed (y). The standard error of the cylindrical object was 0..04 and that of cylindrical body parts of subjects was 0.0407. This technique was validated through the coefficient of correlation for objects and subjects which was found to be 0.99982 and 0.999141 respectively. Accuracy and Precision were also calculated for this model, which were 99.60% accurate and 99.49% precise. Curvature maps were found more than 99%. This technique is inexpensive, reliable, reproducible and may be installed easily in hospitals to examine appraise body shape, composition and deformities of young men.\",\"PeriodicalId\":13063,\"journal\":{\"name\":\"Hygeia J. D.Med.10 (1) August 2018 - January 2019\",\"volume\":\"35 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hygeia J. D.Med.10 (1) August 2018 - January 2019\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22581/muet1982.1901.16\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hygeia J. D.Med.10 (1) August 2018 - January 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22581/muet1982.1901.16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在建立一种更有效、更简单、更准确、更精确地检测和分析物体或主体曲率的光栅立体摄影实验设置标准。首先,需要对装置进行校准,为此我们考虑一个参考平面,使用11个直径在30-119mm之间的不同圆柱体,通过回归线对圆柱体和圆柱体物体的曲率映射进行校准。进一步,我们对这个模型进行了测试,为此我们计算了男孩的圆柱形身体部位,总共有30名大学生参与了这个过程。被测量的身体部位具有不同直径的圆柱体曲率,范围从42-120mm不等。利用不同的工具对栅格变形进行了观察、量化和记录,并建立了结果。得到测量值(x)与计算值(y)之间的回归线,柱状物体的标准误差为0。受试者圆柱形身体部位的平均值为0.0407。通过对象和被试的相关系数分别为0.99982和0.999141,验证了该技术。对该模型进行了准确度和精密度计算,准确度分别为99.60%和99.49%。曲率图的发现率超过99%。该技术价格低廉、可靠、可重复,可方便地安装在医院,用于检查、评估年轻男子的体型、成分和畸形。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Calibration and Validation of an Experimental Setup for the Measurement of the Cylindrical Body Shapes and Curvatures of the Objects and Subjects through the Techniques of Rasterstereography
The intent of study is to establish a criterion for the experimental setup of rasterstereography, one that is more efficient, simple, accurate and precise to examine and analyse the curvature of the object or the subject. Firstly, the setup is needed to be calibrated and for this purpose we considered a reference plane, eleven cylinders of different diameter ranging from 30-119mm were used for calibration of curvature maps of cylinders and cylindrical objects through the regression line. Further this model was tested on subjects and for that we reckoned cylindrical body parts of boys and a total of 30 college students were involved as subjects in this process. The body parts to be measured had curvature like cylinders of different diameters ranging from 42-120mm. The distortion of raster grid was observed, quantified and recorded with the help of different tools and results were established. The regression line was obtained between the measured (x) and computed (y). The standard error of the cylindrical object was 0..04 and that of cylindrical body parts of subjects was 0.0407. This technique was validated through the coefficient of correlation for objects and subjects which was found to be 0.99982 and 0.999141 respectively. Accuracy and Precision were also calculated for this model, which were 99.60% accurate and 99.49% precise. Curvature maps were found more than 99%. This technique is inexpensive, reliable, reproducible and may be installed easily in hospitals to examine appraise body shape, composition and deformities of young men.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信