改进了单个生物细胞的宽带电检测

Y. Ning, X. Ma, C. Multari, X. Luo, V. Gholizadeh, C. Palego, X. Cheng, J. Hwang
{"title":"改进了单个生物细胞的宽带电检测","authors":"Y. Ning, X. Ma, C. Multari, X. Luo, V. Gholizadeh, C. Palego, X. Cheng, J. Hwang","doi":"10.1109/MWSYM.2015.7166722","DOIUrl":null,"url":null,"abstract":"Based on a homemade probe station on top of an inverted microscope for simultaneous microwave measurement and visual validation, broadband detection of live Jurkat cells was successfully extended from 2-3.5 GHz to 0.5-20 GHz with comparable sensitivity and reproducibility. With a carefully optimized coplanar waveguide, closely spaced microwave probes, and frequent calibrations, reference planes were established next to the microfluidic channel, which resulted in smooth and well-behaved scattering parameters without spurious resonances. From the measured scattering parameters, the extracted cytoplasm resistance of 190 kΩ was consistent with the previously reported value but validated over a much wider bandwidth.","PeriodicalId":6493,"journal":{"name":"2015 IEEE MTT-S International Microwave Symposium","volume":"20 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Improved broadband electrical detection of individual biological cells\",\"authors\":\"Y. Ning, X. Ma, C. Multari, X. Luo, V. Gholizadeh, C. Palego, X. Cheng, J. Hwang\",\"doi\":\"10.1109/MWSYM.2015.7166722\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on a homemade probe station on top of an inverted microscope for simultaneous microwave measurement and visual validation, broadband detection of live Jurkat cells was successfully extended from 2-3.5 GHz to 0.5-20 GHz with comparable sensitivity and reproducibility. With a carefully optimized coplanar waveguide, closely spaced microwave probes, and frequent calibrations, reference planes were established next to the microfluidic channel, which resulted in smooth and well-behaved scattering parameters without spurious resonances. From the measured scattering parameters, the extracted cytoplasm resistance of 190 kΩ was consistent with the previously reported value but validated over a much wider bandwidth.\",\"PeriodicalId\":6493,\"journal\":{\"name\":\"2015 IEEE MTT-S International Microwave Symposium\",\"volume\":\"20 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE MTT-S International Microwave Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWSYM.2015.7166722\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE MTT-S International Microwave Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2015.7166722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

基于倒置显微镜顶部自制探针站,实现了对活Jurkat细胞的微波同步测量和视觉验证,成功地将宽带检测范围从2-3.5 GHz扩展到0.5-20 GHz,灵敏度和重现性相当。通过精心优化的共面波导、紧密间隔的微波探针和频繁的校准,在微流控通道附近建立了参考平面,得到了平滑且性能良好的散射参数,没有杂散共振。从测量的散射参数中,提取的细胞质阻力190 kΩ与先前报道的值一致,但在更宽的带宽上验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improved broadband electrical detection of individual biological cells
Based on a homemade probe station on top of an inverted microscope for simultaneous microwave measurement and visual validation, broadband detection of live Jurkat cells was successfully extended from 2-3.5 GHz to 0.5-20 GHz with comparable sensitivity and reproducibility. With a carefully optimized coplanar waveguide, closely spaced microwave probes, and frequent calibrations, reference planes were established next to the microfluidic channel, which resulted in smooth and well-behaved scattering parameters without spurious resonances. From the measured scattering parameters, the extracted cytoplasm resistance of 190 kΩ was consistent with the previously reported value but validated over a much wider bandwidth.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信