Jarosław Milewski, Arkadiusz Szczęśniak, Janusz Lewandowski
{"title":"SOFC/SOEC氢峰电厂辅助设备动态特性研究","authors":"Jarosław Milewski, Arkadiusz Szczęśniak, Janusz Lewandowski","doi":"10.1016/j.ieri.2014.09.045","DOIUrl":null,"url":null,"abstract":"<div><p>The paper presents the 0D models of selected auxiliary equipment of Solid Oxide Fuel/Electrolysis Cell hydrogen peak power plant, i.e., hydrogen compressor, high temperature heat exchanger, and a water pump, which has been calibrated to the appropriate available experimental data. Based on a sensitivity analysis the guidelines for design and operation of these devices are determined for operation with a ceramic fuel cell, electrolyzer, and a tank for compressed hydrogen.</p></div>","PeriodicalId":100649,"journal":{"name":"IERI Procedia","volume":"9 ","pages":"Pages 82-87"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ieri.2014.09.045","citationCount":"12","resultStr":"{\"title\":\"Dynamic Characteristics of Auxiliary Equipment of SOFC/SOEC Hydrogen Peak Power Plant\",\"authors\":\"Jarosław Milewski, Arkadiusz Szczęśniak, Janusz Lewandowski\",\"doi\":\"10.1016/j.ieri.2014.09.045\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The paper presents the 0D models of selected auxiliary equipment of Solid Oxide Fuel/Electrolysis Cell hydrogen peak power plant, i.e., hydrogen compressor, high temperature heat exchanger, and a water pump, which has been calibrated to the appropriate available experimental data. Based on a sensitivity analysis the guidelines for design and operation of these devices are determined for operation with a ceramic fuel cell, electrolyzer, and a tank for compressed hydrogen.</p></div>\",\"PeriodicalId\":100649,\"journal\":{\"name\":\"IERI Procedia\",\"volume\":\"9 \",\"pages\":\"Pages 82-87\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.ieri.2014.09.045\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IERI Procedia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212667814000938\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IERI Procedia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212667814000938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Dynamic Characteristics of Auxiliary Equipment of SOFC/SOEC Hydrogen Peak Power Plant
The paper presents the 0D models of selected auxiliary equipment of Solid Oxide Fuel/Electrolysis Cell hydrogen peak power plant, i.e., hydrogen compressor, high temperature heat exchanger, and a water pump, which has been calibrated to the appropriate available experimental data. Based on a sensitivity analysis the guidelines for design and operation of these devices are determined for operation with a ceramic fuel cell, electrolyzer, and a tank for compressed hydrogen.