{"title":"电生理手术中颈内静脉通路失败后大量血胸:“早期发现-避免灾难”","authors":"P. Harish, O. Satish","doi":"10.4103/jicc.jicc_50_20","DOIUrl":null,"url":null,"abstract":"We report an unusual case of massive hemothorax in a female patient undergoing electrophysiological (EP) procedure for drug-refractory supraventricular tachycardia. She underwent percutaneous intervention with a drug-eluting stent to the right coronary artery 6 months back and was on dual antiplatelet drugs. Timely detection and management of hemothorax prevented a major catastrophe in this patient. This case highlights the importance of keeping a strict vigil for possible occurrence of life-threatening bleeding complications during EP procedure in patients on multiple antiplatelet drug therapy.","PeriodicalId":100789,"journal":{"name":"Journal of Indian College of Cardiology","volume":"41 1","pages":"139 - 141"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Massive hemothorax following failed internal jugular vein access during an electrophysiological procedure: “Early detection – catastrophe averted”\",\"authors\":\"P. Harish, O. Satish\",\"doi\":\"10.4103/jicc.jicc_50_20\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report an unusual case of massive hemothorax in a female patient undergoing electrophysiological (EP) procedure for drug-refractory supraventricular tachycardia. She underwent percutaneous intervention with a drug-eluting stent to the right coronary artery 6 months back and was on dual antiplatelet drugs. Timely detection and management of hemothorax prevented a major catastrophe in this patient. This case highlights the importance of keeping a strict vigil for possible occurrence of life-threatening bleeding complications during EP procedure in patients on multiple antiplatelet drug therapy.\",\"PeriodicalId\":100789,\"journal\":{\"name\":\"Journal of Indian College of Cardiology\",\"volume\":\"41 1\",\"pages\":\"139 - 141\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian College of Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jicc.jicc_50_20\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian College of Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jicc.jicc_50_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Massive hemothorax following failed internal jugular vein access during an electrophysiological procedure: “Early detection – catastrophe averted”
We report an unusual case of massive hemothorax in a female patient undergoing electrophysiological (EP) procedure for drug-refractory supraventricular tachycardia. She underwent percutaneous intervention with a drug-eluting stent to the right coronary artery 6 months back and was on dual antiplatelet drugs. Timely detection and management of hemothorax prevented a major catastrophe in this patient. This case highlights the importance of keeping a strict vigil for possible occurrence of life-threatening bleeding complications during EP procedure in patients on multiple antiplatelet drug therapy.