Ubidecarenone颗粒和细颗粒在光照下的稳定性和分解物质

M. Hirahara, Masafumi Ogawa, M. Shigematsu, K. Nagayama, A. Satake, K. Hori, Itsumi Miyabe
{"title":"Ubidecarenone颗粒和细颗粒在光照下的稳定性和分解物质","authors":"M. Hirahara, Masafumi Ogawa, M. Shigematsu, K. Nagayama, A. Satake, K. Hori, Itsumi Miyabe","doi":"10.5649/JJPHCS1975.9.384","DOIUrl":null,"url":null,"abstract":"(Received May 20, 1983) A high performance liquid chromatograph (HPLC) was used for the quality test of Ubidecarenone (CoQ10) products. CoQ10 products were exposed to light under 2000 lux for 29 days, and their stability to light was studied with HPLC. The results were as follows: 1) Good separation of CoQ10. CoQ9 and UC9 was achieved with HPLC. 2) The amount of CoQ10 in granules and fine granules packed with Pile Packer Film was between 11% and 18% after 29day exposure to light, whereas CoQ10 in granules in lightshielded package and that in raw material powder packed with pile packer Film were 74% and 90%, respectively. 3) The main decomposition substance of the granules, the fine granules and raw material powder showed that the relative retention to CoQ10 was 0.49. Keywordsubidecarenone; ubichromenol9; quality test; stability to light","PeriodicalId":17399,"journal":{"name":"Journal of the Nippon Hospital Pharmacists Association","volume":"29 1","pages":"384-388"},"PeriodicalIF":0.0000,"publicationDate":"1983-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Stability and Decomposition Substances of Ubidecarenone Granules and Fine Granules on Exposure to Light\",\"authors\":\"M. Hirahara, Masafumi Ogawa, M. Shigematsu, K. Nagayama, A. Satake, K. Hori, Itsumi Miyabe\",\"doi\":\"10.5649/JJPHCS1975.9.384\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"(Received May 20, 1983) A high performance liquid chromatograph (HPLC) was used for the quality test of Ubidecarenone (CoQ10) products. CoQ10 products were exposed to light under 2000 lux for 29 days, and their stability to light was studied with HPLC. The results were as follows: 1) Good separation of CoQ10. CoQ9 and UC9 was achieved with HPLC. 2) The amount of CoQ10 in granules and fine granules packed with Pile Packer Film was between 11% and 18% after 29day exposure to light, whereas CoQ10 in granules in lightshielded package and that in raw material powder packed with pile packer Film were 74% and 90%, respectively. 3) The main decomposition substance of the granules, the fine granules and raw material powder showed that the relative retention to CoQ10 was 0.49. Keywordsubidecarenone; ubichromenol9; quality test; stability to light\",\"PeriodicalId\":17399,\"journal\":{\"name\":\"Journal of the Nippon Hospital Pharmacists Association\",\"volume\":\"29 1\",\"pages\":\"384-388\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Nippon Hospital Pharmacists Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5649/JJPHCS1975.9.384\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Nippon Hospital Pharmacists Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5649/JJPHCS1975.9.384","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

(收于1983年5月20日)采用高效液相色谱仪(HPLC)对乌比迪卡酮(CoQ10)产品进行了质量检测。将CoQ10产品在2000勒克斯的光照下暴露29 d,用高效液相色谱法研究其对光的稳定性。结果表明:1)CoQ10分离效果良好。高效液相色谱法测定CoQ9和UC9。2)经光照29d后,颗粒和细粒中辅酶q10含量在11% ~ 18%之间,遮光包装颗粒中辅酶q10含量为74%,原料粉中辅酶q10含量为90%。3)颗粒、细粒和原料粉的主要分解物质对辅酶q10的相对保留率为0.49。Keywordsubidecarenone;ubichromenol9;质量检验;对光稳定性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Stability and Decomposition Substances of Ubidecarenone Granules and Fine Granules on Exposure to Light
(Received May 20, 1983) A high performance liquid chromatograph (HPLC) was used for the quality test of Ubidecarenone (CoQ10) products. CoQ10 products were exposed to light under 2000 lux for 29 days, and their stability to light was studied with HPLC. The results were as follows: 1) Good separation of CoQ10. CoQ9 and UC9 was achieved with HPLC. 2) The amount of CoQ10 in granules and fine granules packed with Pile Packer Film was between 11% and 18% after 29day exposure to light, whereas CoQ10 in granules in lightshielded package and that in raw material powder packed with pile packer Film were 74% and 90%, respectively. 3) The main decomposition substance of the granules, the fine granules and raw material powder showed that the relative retention to CoQ10 was 0.49. Keywordsubidecarenone; ubichromenol9; quality test; stability to light
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信