自动检测系统对凝血试验分析前筛选干扰的改进

Q4 Health Professions
Zhiqi Gao, Huimin Yuan, Qi Zhou, Qingtao Wang
{"title":"自动检测系统对凝血试验分析前筛选干扰的改进","authors":"Zhiqi Gao, Huimin Yuan, Qi Zhou, Qingtao Wang","doi":"10.3760/CMA.J.ISSN.1009-9158.2019.11.012","DOIUrl":null,"url":null,"abstract":"Objective \nTo investigate the potential improvement of sample quality by automatic pre-analysis sample checking system, comparing to visual inspection for coagulation tests routinely. \n \n \nMethods \nThirty samples with hemolysis, Icteric and lipemia in different levels were prepared and issued to 13 technicians for visual check, to evaluate the consistency individually. 2 949 blood samples with order for coagulation test were collected in Beijing Chaoyang Hospital in April and May 2018, the quality of all samples was evaluated by both visual check and automatic sample quality checking system before analysis, performance of two measurements detecting hemolysis, lipid, icteric or clot was compared. \n \n \nResults \nSignificant differences were found in visual check among operators. The Kappa coefficients in three randomly selected groups were 0.32, 0.26 and 0.38 respectively, indicating that the consistency of visual check was poor. Among all investigated samples, 3 samples with unacceptable interference were detected visually, including 2 samples with hemolysis and another one with lipemia. On the other hand, 19 unqualified samples were identified by automatic checking system. Five types of interference of unqualified samples were detected as icteric (26.32%,5/19), clot (21.05%,4/19) hemolysis (5.26%,1/19),lipemia (36.84%, 7/19), and hemolysis with lipemia (10.53%,2/19) respectively by automatic checking system. But one case of hemolysis sample rejected by visual check was not rejected by automatic sample quality checking system.7 samples were merely affected on D-dimer by lipemia, which level did not influence the results of prothrombin time(PT) and activated partial thromboplastin time (APTT). Notably, other two samples were interfered with not only tests of PT, APTT and fibrinogen by hemolysis, but also D-dimer by the considerable level of lipemia, which showed the superiority of test-specific quality checking features. \n \n \nConclusions \nThe automatic pre-analysis sample quality checking system can improve the detection rate of unqualified samples and improve the efficiency of routine, helping realization of total quality management. \n \n \nKey words: \nSampling; Coagulation test; Total quality management","PeriodicalId":10096,"journal":{"name":"中华检验医学杂志","volume":"43 1","pages":"962-966"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improvement of preanalytical screening interference on coagulation tests by auto checking system\",\"authors\":\"Zhiqi Gao, Huimin Yuan, Qi Zhou, Qingtao Wang\",\"doi\":\"10.3760/CMA.J.ISSN.1009-9158.2019.11.012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo investigate the potential improvement of sample quality by automatic pre-analysis sample checking system, comparing to visual inspection for coagulation tests routinely. \\n \\n \\nMethods \\nThirty samples with hemolysis, Icteric and lipemia in different levels were prepared and issued to 13 technicians for visual check, to evaluate the consistency individually. 2 949 blood samples with order for coagulation test were collected in Beijing Chaoyang Hospital in April and May 2018, the quality of all samples was evaluated by both visual check and automatic sample quality checking system before analysis, performance of two measurements detecting hemolysis, lipid, icteric or clot was compared. \\n \\n \\nResults \\nSignificant differences were found in visual check among operators. The Kappa coefficients in three randomly selected groups were 0.32, 0.26 and 0.38 respectively, indicating that the consistency of visual check was poor. Among all investigated samples, 3 samples with unacceptable interference were detected visually, including 2 samples with hemolysis and another one with lipemia. On the other hand, 19 unqualified samples were identified by automatic checking system. Five types of interference of unqualified samples were detected as icteric (26.32%,5/19), clot (21.05%,4/19) hemolysis (5.26%,1/19),lipemia (36.84%, 7/19), and hemolysis with lipemia (10.53%,2/19) respectively by automatic checking system. But one case of hemolysis sample rejected by visual check was not rejected by automatic sample quality checking system.7 samples were merely affected on D-dimer by lipemia, which level did not influence the results of prothrombin time(PT) and activated partial thromboplastin time (APTT). Notably, other two samples were interfered with not only tests of PT, APTT and fibrinogen by hemolysis, but also D-dimer by the considerable level of lipemia, which showed the superiority of test-specific quality checking features. \\n \\n \\nConclusions \\nThe automatic pre-analysis sample quality checking system can improve the detection rate of unqualified samples and improve the efficiency of routine, helping realization of total quality management. \\n \\n \\nKey words: \\nSampling; Coagulation test; Total quality management\",\"PeriodicalId\":10096,\"journal\":{\"name\":\"中华检验医学杂志\",\"volume\":\"43 1\",\"pages\":\"962-966\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华检验医学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1009-9158.2019.11.012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华检验医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1009-9158.2019.11.012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

摘要

目的探讨自动预分析检样系统与常规目测凝血检测相比对样品质量的改善潜力。方法制备不同程度的溶血、黄疸、血脂标本30份,发给13名技术人员目视检查,分别进行一致性评价。2018年4月至5月在北京市朝阳医院采集了2 949份有凝血检查单的血液样本,分析前采用目测和自动质量检测系统对所有样本进行质量评价,比较溶血、脂质、黄疸或凝块两种检测方法的性能。结果操作人员在目视检查方面存在显著差异。随机选取的三组Kappa系数分别为0.32、0.26和0.38,说明目测一致性较差。在所有调查样本中,目测干扰不可接受的样本有3个,其中溶血2个,血脂1个。另一方面,通过自动检测系统鉴定出19份不合格样品。自动检测系统检测出不合格样品的干扰类型分别为黄疸(26.32%,5/19)、血栓(21.05%,4/19)、溶血(5.26%,1/19)、血脂(36.84%,7/19)、溶血伴血脂(10.53%,2/19)。但有1例溶血样品目测不合格,自动质量检测系统不合格。7份样品仅受脂血症影响d -二聚体,其水平不影响凝血酶原时间(PT)和活化部分凝血活素时间(APTT)的结果。值得注意的是,另外两份样品不仅受到溶血对PT、APTT和纤维蛋白原检测的干扰,还受到相当程度的脂血症对d -二聚体检测的干扰,显示出检测特异性质量检查功能的优越性。结论分析前样品质量自动检测系统可提高不合格样品的检出率,提高常规工作效率,有利于全面质量管理的实现。关键词:抽样;凝血试验;全面质量管理
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improvement of preanalytical screening interference on coagulation tests by auto checking system
Objective To investigate the potential improvement of sample quality by automatic pre-analysis sample checking system, comparing to visual inspection for coagulation tests routinely. Methods Thirty samples with hemolysis, Icteric and lipemia in different levels were prepared and issued to 13 technicians for visual check, to evaluate the consistency individually. 2 949 blood samples with order for coagulation test were collected in Beijing Chaoyang Hospital in April and May 2018, the quality of all samples was evaluated by both visual check and automatic sample quality checking system before analysis, performance of two measurements detecting hemolysis, lipid, icteric or clot was compared. Results Significant differences were found in visual check among operators. The Kappa coefficients in three randomly selected groups were 0.32, 0.26 and 0.38 respectively, indicating that the consistency of visual check was poor. Among all investigated samples, 3 samples with unacceptable interference were detected visually, including 2 samples with hemolysis and another one with lipemia. On the other hand, 19 unqualified samples were identified by automatic checking system. Five types of interference of unqualified samples were detected as icteric (26.32%,5/19), clot (21.05%,4/19) hemolysis (5.26%,1/19),lipemia (36.84%, 7/19), and hemolysis with lipemia (10.53%,2/19) respectively by automatic checking system. But one case of hemolysis sample rejected by visual check was not rejected by automatic sample quality checking system.7 samples were merely affected on D-dimer by lipemia, which level did not influence the results of prothrombin time(PT) and activated partial thromboplastin time (APTT). Notably, other two samples were interfered with not only tests of PT, APTT and fibrinogen by hemolysis, but also D-dimer by the considerable level of lipemia, which showed the superiority of test-specific quality checking features. Conclusions The automatic pre-analysis sample quality checking system can improve the detection rate of unqualified samples and improve the efficiency of routine, helping realization of total quality management. Key words: Sampling; Coagulation test; Total quality management
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华检验医学杂志
中华检验医学杂志 Health Professions-Medical Laboratory Technology
CiteScore
0.40
自引率
0.00%
发文量
8037
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信