谐波雷达生命体征检测系统的噪声与灵敏度分析

L. Chioukh, H. Boutayeb, D. Deslandes, K. Wu
{"title":"谐波雷达生命体征检测系统的噪声与灵敏度分析","authors":"L. Chioukh, H. Boutayeb, D. Deslandes, K. Wu","doi":"10.1109/IMWS-BIO.2013.6756192","DOIUrl":null,"url":null,"abstract":"Harmonic radar architectures present systems of wireless detection operating at multiple harmonic carrier frequencies. The noise and sensitivity of a harmonic radar system, which is developed at 12 GHz and 24 GHz for vital signs detection, are studied numerically and experimentally. The received signal power of the radar system is analyzed numerically as a function of the distance, taking into account the radar cross section (RCS) of the patient chest. The numerical data are compared with results obtained with single carrier frequency system. The total noise is a combination of thermal noise, residual phase noise, and flicker noise that presents the most elevated factor influencing the detection at baseband. Experimental results show that with the harmonic radar, the flicker noise can be reduced by 20dB at around 1Hz baseband frequency.","PeriodicalId":6321,"journal":{"name":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","volume":"127 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Noise and sensitivity analysis of harmonic radar system for vital sign detection\",\"authors\":\"L. Chioukh, H. Boutayeb, D. Deslandes, K. Wu\",\"doi\":\"10.1109/IMWS-BIO.2013.6756192\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Harmonic radar architectures present systems of wireless detection operating at multiple harmonic carrier frequencies. The noise and sensitivity of a harmonic radar system, which is developed at 12 GHz and 24 GHz for vital signs detection, are studied numerically and experimentally. The received signal power of the radar system is analyzed numerically as a function of the distance, taking into account the radar cross section (RCS) of the patient chest. The numerical data are compared with results obtained with single carrier frequency system. The total noise is a combination of thermal noise, residual phase noise, and flicker noise that presents the most elevated factor influencing the detection at baseband. Experimental results show that with the harmonic radar, the flicker noise can be reduced by 20dB at around 1Hz baseband frequency.\",\"PeriodicalId\":6321,\"journal\":{\"name\":\"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)\",\"volume\":\"127 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMWS-BIO.2013.6756192\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMWS-BIO.2013.6756192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

谐波雷达架构提出了在多个谐波载波频率下工作的无线探测系统。对12 GHz和24 GHz谐波雷达系统的噪声和灵敏度进行了数值和实验研究。在考虑患者胸部雷达截面(RCS)的情况下,对雷达系统接收信号功率作为距离的函数进行了数值分析。数值数据与单载波系统得到的结果进行了比较。总噪声是热噪声、剩余相位噪声和闪烁噪声的组合,是影响基带检测的最高因素。实验结果表明,在基带频率为1Hz左右时,谐波雷达的闪烁噪声可降低20dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Noise and sensitivity analysis of harmonic radar system for vital sign detection
Harmonic radar architectures present systems of wireless detection operating at multiple harmonic carrier frequencies. The noise and sensitivity of a harmonic radar system, which is developed at 12 GHz and 24 GHz for vital signs detection, are studied numerically and experimentally. The received signal power of the radar system is analyzed numerically as a function of the distance, taking into account the radar cross section (RCS) of the patient chest. The numerical data are compared with results obtained with single carrier frequency system. The total noise is a combination of thermal noise, residual phase noise, and flicker noise that presents the most elevated factor influencing the detection at baseband. Experimental results show that with the harmonic radar, the flicker noise can be reduced by 20dB at around 1Hz baseband frequency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信