{"title":"使用开源软件测量眼眶体积及其在眼眶颧骨骨折中的应用","authors":"Taradevi P V Narayan, Vikas Dhupar","doi":"10.1177/19433875231163982","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>Technical note.</p><p><strong>Objective: </strong>Changes in orbital volume can lead to esthetic and functional complications of the orbit. In this article, the procedure to calculate the orbital volume using the open source software Aliza 3D DICOM is described.</p><p><strong>Methods: </strong>This article describes the steps to use this novel software. To validate the software, the normal orbital volume was calculated bilaterally on CT scans with normal orbital anatomy. The volumes of unilateral orbitozygomatic fracture cases were compared.</p><p><strong>Results: </strong>This open source software has easy access. The normal orbital volume calculated using this software was 24.4 cc ± 0.72. In the unilateral orbitozygomatic fracture cases, an increased orbital volume was calculated.</p><p><strong>Conclusions: </strong>This easy access, inexpensive, and convenient computer aided software can be used to calculate orbital volume facilitating treatment plan for correction of the orbit volume.</p>","PeriodicalId":46447,"journal":{"name":"Craniomaxillofacial Trauma & Reconstruction","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11107815/pdf/","citationCount":"0","resultStr":"{\"title\":\"Measuring orbital Volume Using Open Source Software and its Application in Orbitozygomatic Fractures.\",\"authors\":\"Taradevi P V Narayan, Vikas Dhupar\",\"doi\":\"10.1177/19433875231163982\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>Technical note.</p><p><strong>Objective: </strong>Changes in orbital volume can lead to esthetic and functional complications of the orbit. In this article, the procedure to calculate the orbital volume using the open source software Aliza 3D DICOM is described.</p><p><strong>Methods: </strong>This article describes the steps to use this novel software. To validate the software, the normal orbital volume was calculated bilaterally on CT scans with normal orbital anatomy. The volumes of unilateral orbitozygomatic fracture cases were compared.</p><p><strong>Results: </strong>This open source software has easy access. The normal orbital volume calculated using this software was 24.4 cc ± 0.72. In the unilateral orbitozygomatic fracture cases, an increased orbital volume was calculated.</p><p><strong>Conclusions: </strong>This easy access, inexpensive, and convenient computer aided software can be used to calculate orbital volume facilitating treatment plan for correction of the orbit volume.</p>\",\"PeriodicalId\":46447,\"journal\":{\"name\":\"Craniomaxillofacial Trauma & Reconstruction\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11107815/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Craniomaxillofacial Trauma & Reconstruction\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/19433875231163982\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/3/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Craniomaxillofacial Trauma & Reconstruction","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19433875231163982","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/16 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
研究设计:技术说明:眼眶容积的变化可导致眼眶的美学和功能并发症。本文介绍了使用开源软件 Aliza 3D DICOM 计算眼眶体积的过程:本文介绍了使用这款新型软件的步骤。为了验证该软件的有效性,在具有正常眼眶解剖结构的 CT 扫描上计算了双侧正常眼眶体积。结果:结果:该开源软件易于使用。使用该软件计算出的正常眼眶体积为 24.4 cc ± 0.72。在单侧眶颧骨骨折病例中,计算出的眶体积有所增加:结论:这款操作简便、价格低廉的计算机辅助软件可用于计算眼眶体积,有助于制定矫正眼眶体积的治疗方案。
Measuring orbital Volume Using Open Source Software and its Application in Orbitozygomatic Fractures.
Study design: Technical note.
Objective: Changes in orbital volume can lead to esthetic and functional complications of the orbit. In this article, the procedure to calculate the orbital volume using the open source software Aliza 3D DICOM is described.
Methods: This article describes the steps to use this novel software. To validate the software, the normal orbital volume was calculated bilaterally on CT scans with normal orbital anatomy. The volumes of unilateral orbitozygomatic fracture cases were compared.
Results: This open source software has easy access. The normal orbital volume calculated using this software was 24.4 cc ± 0.72. In the unilateral orbitozygomatic fracture cases, an increased orbital volume was calculated.
Conclusions: This easy access, inexpensive, and convenient computer aided software can be used to calculate orbital volume facilitating treatment plan for correction of the orbit volume.