{"title":"使用基于电压控制的改进DSTATCOM缓解电能质量问题","authors":"A. Abdelsalam, M. A. Kabeel, A. Sallam","doi":"10.1080/1448837X.2022.2112308","DOIUrl":null,"url":null,"abstract":"ABSTRACT This paper proposes a modified distribution static compensator (DSTATCOM) with the voltage controller. The modified DSTATCOM is incorporated in a three-phase four-wire distribution network. The design criteria of the modified DSTATCOM parameters is introduced. The Hysteresis Voltage Controller (HVC) is used to drive the Voltage Source Converter (VSC) and its reference voltage signal is generated based on the Instantaneous Symmetrical Components Theory (ISCT) to provide the proper compensation to stabilise the system voltage, improve the power factor and mitigate the harmonic distortion. Matlab/Simulink software is used to verify the performance of the modified DSTATCOM with the used controller under different load types and supply voltage conditions. The control algorithm ensures that the bus voltage is maintained at its rated value during different connected loads and supply conditions. Also, it compensates the non-linear and unbalanced supply currents and reducing the Total Harmonic Distortion (THD) of both current and voltage. The proposed modified DSTATCOM gives better results in comparison with the conventional DSTATCOM.","PeriodicalId":34935,"journal":{"name":"Australian Journal of Electrical and Electronics Engineering","volume":"21 1","pages":"122 - 137"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mitigation of power quality problems using voltage-controlled based modified DSTATCOM\",\"authors\":\"A. Abdelsalam, M. A. Kabeel, A. Sallam\",\"doi\":\"10.1080/1448837X.2022.2112308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT This paper proposes a modified distribution static compensator (DSTATCOM) with the voltage controller. The modified DSTATCOM is incorporated in a three-phase four-wire distribution network. The design criteria of the modified DSTATCOM parameters is introduced. The Hysteresis Voltage Controller (HVC) is used to drive the Voltage Source Converter (VSC) and its reference voltage signal is generated based on the Instantaneous Symmetrical Components Theory (ISCT) to provide the proper compensation to stabilise the system voltage, improve the power factor and mitigate the harmonic distortion. Matlab/Simulink software is used to verify the performance of the modified DSTATCOM with the used controller under different load types and supply voltage conditions. The control algorithm ensures that the bus voltage is maintained at its rated value during different connected loads and supply conditions. Also, it compensates the non-linear and unbalanced supply currents and reducing the Total Harmonic Distortion (THD) of both current and voltage. The proposed modified DSTATCOM gives better results in comparison with the conventional DSTATCOM.\",\"PeriodicalId\":34935,\"journal\":{\"name\":\"Australian Journal of Electrical and Electronics Engineering\",\"volume\":\"21 1\",\"pages\":\"122 - 137\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australian Journal of Electrical and Electronics Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/1448837X.2022.2112308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian Journal of Electrical and Electronics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/1448837X.2022.2112308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Mitigation of power quality problems using voltage-controlled based modified DSTATCOM
ABSTRACT This paper proposes a modified distribution static compensator (DSTATCOM) with the voltage controller. The modified DSTATCOM is incorporated in a three-phase four-wire distribution network. The design criteria of the modified DSTATCOM parameters is introduced. The Hysteresis Voltage Controller (HVC) is used to drive the Voltage Source Converter (VSC) and its reference voltage signal is generated based on the Instantaneous Symmetrical Components Theory (ISCT) to provide the proper compensation to stabilise the system voltage, improve the power factor and mitigate the harmonic distortion. Matlab/Simulink software is used to verify the performance of the modified DSTATCOM with the used controller under different load types and supply voltage conditions. The control algorithm ensures that the bus voltage is maintained at its rated value during different connected loads and supply conditions. Also, it compensates the non-linear and unbalanced supply currents and reducing the Total Harmonic Distortion (THD) of both current and voltage. The proposed modified DSTATCOM gives better results in comparison with the conventional DSTATCOM.