D.L. Smith, P. Ingwersen, L. Bennett, J. Boyes, D.E. Anderson, J. Greenly, R. Sudan, D. Hammer
{"title":"用于康奈尔/桑迪亚ICF研究的COBRA加速器脉冲动力驱动器","authors":"D.L. Smith, P. Ingwersen, L. Bennett, J. Boyes, D.E. Anderson, J. Greenly, R. Sudan, D. Hammer","doi":"10.1109/PPC.1995.599821","DOIUrl":null,"url":null,"abstract":"This paper introduces and describes the new Cornell Beam Research Accelerator, COBRA, the result of a three and one-half year collaboration. The flexible 4 to 5-MV, 100 to 250-kA, 46-ns pulse width accelerator is based on a four-cavity inductive voltage adder (IVA) design. In addition to being a mix of new and existing components, COBRA is unique in the sense that each cavity is driven by a single pulse forming line, and the IVA output polarity may be reversed by rotating the cavities 180/spl deg/ about their vertical axis. Our tests with negative high voltage on the inner MITL stalk indicate that the vacuum power flow has established reasonable azimuthal symmetry within about 2 ns (or 0.6 m) after the cavity output gap. Preliminary results with the accelerator, single cavity, and MITL are presented along with the design details and circuit model predictions.","PeriodicalId":11163,"journal":{"name":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","volume":"13 1","pages":"1449-1454 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1995-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The COBRA accelerator pulsed-power driver for Cornell/Sandia ICF research\",\"authors\":\"D.L. Smith, P. Ingwersen, L. Bennett, J. Boyes, D.E. Anderson, J. Greenly, R. Sudan, D. Hammer\",\"doi\":\"10.1109/PPC.1995.599821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces and describes the new Cornell Beam Research Accelerator, COBRA, the result of a three and one-half year collaboration. The flexible 4 to 5-MV, 100 to 250-kA, 46-ns pulse width accelerator is based on a four-cavity inductive voltage adder (IVA) design. In addition to being a mix of new and existing components, COBRA is unique in the sense that each cavity is driven by a single pulse forming line, and the IVA output polarity may be reversed by rotating the cavities 180/spl deg/ about their vertical axis. Our tests with negative high voltage on the inner MITL stalk indicate that the vacuum power flow has established reasonable azimuthal symmetry within about 2 ns (or 0.6 m) after the cavity output gap. Preliminary results with the accelerator, single cavity, and MITL are presented along with the design details and circuit model predictions.\",\"PeriodicalId\":11163,\"journal\":{\"name\":\"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference\",\"volume\":\"13 1\",\"pages\":\"1449-1454 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.1995.599821\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1995.599821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
本文介绍并描述了新的康奈尔束流研究加速器COBRA,这是一个为期三年半的合作成果。灵活的4至5 mv, 100至250 ka, 46-ns脉冲宽度加速器基于四腔电感电压加法器(IVA)设计。除了混合了新组件和现有组件外,COBRA的独特之处在于每个腔都由单个脉冲形成线驱动,并且IVA输出极性可以通过围绕其垂直轴旋转180/spl度来反转。在MITL内杆负高压下的实验表明,真空功率流在空腔输出间隙后约2ns (0.6 m)内建立了合理的方位角对称性。介绍了加速器、单腔和MITL的初步结果,以及设计细节和电路模型预测。
The COBRA accelerator pulsed-power driver for Cornell/Sandia ICF research
This paper introduces and describes the new Cornell Beam Research Accelerator, COBRA, the result of a three and one-half year collaboration. The flexible 4 to 5-MV, 100 to 250-kA, 46-ns pulse width accelerator is based on a four-cavity inductive voltage adder (IVA) design. In addition to being a mix of new and existing components, COBRA is unique in the sense that each cavity is driven by a single pulse forming line, and the IVA output polarity may be reversed by rotating the cavities 180/spl deg/ about their vertical axis. Our tests with negative high voltage on the inner MITL stalk indicate that the vacuum power flow has established reasonable azimuthal symmetry within about 2 ns (or 0.6 m) after the cavity output gap. Preliminary results with the accelerator, single cavity, and MITL are presented along with the design details and circuit model predictions.