Lai Chin Yung, C. C. Fei
{"title":"用能量色散x射线验证薄膜金属层厚度","authors":"Lai Chin Yung, C. C. Fei","doi":"10.1109/RSM.2015.7355004","DOIUrl":null,"url":null,"abstract":"Leadframe fabrication process normally involves additional thin film metal layer plating on the bulk copper substrate surface for wire bond purpose. The recent commonly adopted plating materials are silver, tin, and copper flake. To assess the thickness quality, the conventional X-section methods involving grinding and polishing process are utilized. However, the process may lead to inaccurate results, which stems from the occurrence of sample preparation artifact, such as smearing effect attributable to the grinding or polishing process. Thus, alternative advanced methods are developed for assessing the thin film metal layer thickness, such as Focus Ion Beam (FIB), SIMS profiling or XPS, readily available in worldwide market. However, these alternative measurement services are very costly and time consuming per sample measure. To cater the cost and long sample preparation time due to the abovementioned advanced methods, an Energy Dispersive X-ray (EDX) can be applied. In this study, the newly invented methodology breakthrough had been validated by applying EDX for the first time on known bulk elemental analysis purpose. EDX feature is not only useful for elemental analysis but also applicable for thin film-metal layer thickness measurement and bulk material densification determination. A promising result was observed from the detailed experiment work through applying EDX in this evaluation.","PeriodicalId":6667,"journal":{"name":"2015 IEEE Regional Symposium on Micro and Nanoelectronics (RSM)","volume":"14 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Verification of the thin film metal layer thickness by energy dispersive X-ray\",\"authors\":\"Lai Chin Yung, C. C. Fei\",\"doi\":\"10.1109/RSM.2015.7355004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Leadframe fabrication process normally involves additional thin film metal layer plating on the bulk copper substrate surface for wire bond purpose. The recent commonly adopted plating materials are silver, tin, and copper flake. To assess the thickness quality, the conventional X-section methods involving grinding and polishing process are utilized. However, the process may lead to inaccurate results, which stems from the occurrence of sample preparation artifact, such as smearing effect attributable to the grinding or polishing process. Thus, alternative advanced methods are developed for assessing the thin film metal layer thickness, such as Focus Ion Beam (FIB), SIMS profiling or XPS, readily available in worldwide market. However, these alternative measurement services are very costly and time consuming per sample measure. To cater the cost and long sample preparation time due to the abovementioned advanced methods, an Energy Dispersive X-ray (EDX) can be applied. In this study, the newly invented methodology breakthrough had been validated by applying EDX for the first time on known bulk elemental analysis purpose. EDX feature is not only useful for elemental analysis but also applicable for thin film-metal layer thickness measurement and bulk material densification determination. A promising result was observed from the detailed experiment work through applying EDX in this evaluation.\",\"PeriodicalId\":6667,\"journal\":{\"name\":\"2015 IEEE Regional Symposium on Micro and Nanoelectronics (RSM)\",\"volume\":\"14 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Regional Symposium on Micro and Nanoelectronics (RSM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RSM.2015.7355004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Regional Symposium on Micro and Nanoelectronics (RSM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RSM.2015.7355004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

引线框架的制造过程通常涉及在大块铜基板表面镀上额外的薄膜金属层,用于导线粘合目的。目前普遍采用的电镀材料有银、锡、铜片等。为了评估厚度质量,采用了传统的x -切片方法,包括研磨和抛光过程。然而,该过程可能导致不准确的结果,这源于样品制备伪影的发生,例如由于研磨或抛光过程造成的涂抹效应。因此,用于评估薄膜金属层厚度的替代先进方法被开发出来,例如焦点离子束(FIB), SIMS分析或XPS,在全球市场上都很容易获得。然而,这些可选的测量服务对于每个样本测量都非常昂贵和耗时。由于上述先进方法的成本和样品制备时间长,可以使用能量色散x射线(EDX)。在本研究中,首次将EDX应用于已知的体元素分析目的,验证了新发明的方法突破。EDX特征不仅可用于元素分析,还可用于薄膜-金属层厚度测量和块状材料密度测定。通过详细的实验工作,将EDX应用于该评价中,得到了令人满意的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Verification of the thin film metal layer thickness by energy dispersive X-ray
Leadframe fabrication process normally involves additional thin film metal layer plating on the bulk copper substrate surface for wire bond purpose. The recent commonly adopted plating materials are silver, tin, and copper flake. To assess the thickness quality, the conventional X-section methods involving grinding and polishing process are utilized. However, the process may lead to inaccurate results, which stems from the occurrence of sample preparation artifact, such as smearing effect attributable to the grinding or polishing process. Thus, alternative advanced methods are developed for assessing the thin film metal layer thickness, such as Focus Ion Beam (FIB), SIMS profiling or XPS, readily available in worldwide market. However, these alternative measurement services are very costly and time consuming per sample measure. To cater the cost and long sample preparation time due to the abovementioned advanced methods, an Energy Dispersive X-ray (EDX) can be applied. In this study, the newly invented methodology breakthrough had been validated by applying EDX for the first time on known bulk elemental analysis purpose. EDX feature is not only useful for elemental analysis but also applicable for thin film-metal layer thickness measurement and bulk material densification determination. A promising result was observed from the detailed experiment work through applying EDX in this evaluation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信