R. Roberts, C. Szelc, S. Scates, M. T. Boyd, K. Soderstrom, M. W. Davis, J. Glaspy
{"title":"用重组人粒细胞集落刺激因子治疗极早产儿中性粒细胞减少症。","authors":"R. Roberts, C. Szelc, S. Scates, M. T. Boyd, K. Soderstrom, M. W. Davis, J. Glaspy","doi":"10.1001/ARCHPEDI.1991.02160070104030","DOIUrl":null,"url":null,"abstract":"Neutropenia in the newborn is often associated with sepsis, maternal hypertension, or prematurity. We describe a 654-g infant born at 30 weeks' gestation by cesarean section due to severe maternal hypertension. His course was complicated by five episodes of sepsis, including three with group B streptococcus. The results of hematologic and immunologic studies were normal except that absolute neutrophil counts were low (less than 1 x 10(9)/L) with intermittent increases during sepsis. Human recombinant granulocyte colony-stimulating factor administered subcutaneously (10 micrograms/kg per day initially) resulted in an absolute neutrophil count of greater than 30 x 10(9)/L within 2 weeks. The dosage was lowered and the absolute neutrophil counts were maintained at 8 to 12 x 10(9)/L with no further septic episodes. The human recombinant granulocyte colony-stimulating factor therapy was discontinued after 7 months, and the patient remained healthy with an absolute neutrophil count of greater than 2 x 10(9)/L. Thus, treatment with human recombinant granulocyte colony-stimulating factor may be useful as a temporary measure for neonatal neutropenia associated with sepsis. A controlled, clinical trial is warranted.","PeriodicalId":7654,"journal":{"name":"American journal of diseases of children","volume":"8 1","pages":"808-12"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"47","resultStr":"{\"title\":\"Neutropenia in an extremely premature infant treated with recombinant human granulocyte colony-stimulating factor.\",\"authors\":\"R. Roberts, C. Szelc, S. Scates, M. T. Boyd, K. Soderstrom, M. W. Davis, J. Glaspy\",\"doi\":\"10.1001/ARCHPEDI.1991.02160070104030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Neutropenia in the newborn is often associated with sepsis, maternal hypertension, or prematurity. We describe a 654-g infant born at 30 weeks' gestation by cesarean section due to severe maternal hypertension. His course was complicated by five episodes of sepsis, including three with group B streptococcus. The results of hematologic and immunologic studies were normal except that absolute neutrophil counts were low (less than 1 x 10(9)/L) with intermittent increases during sepsis. Human recombinant granulocyte colony-stimulating factor administered subcutaneously (10 micrograms/kg per day initially) resulted in an absolute neutrophil count of greater than 30 x 10(9)/L within 2 weeks. The dosage was lowered and the absolute neutrophil counts were maintained at 8 to 12 x 10(9)/L with no further septic episodes. The human recombinant granulocyte colony-stimulating factor therapy was discontinued after 7 months, and the patient remained healthy with an absolute neutrophil count of greater than 2 x 10(9)/L. Thus, treatment with human recombinant granulocyte colony-stimulating factor may be useful as a temporary measure for neonatal neutropenia associated with sepsis. A controlled, clinical trial is warranted.\",\"PeriodicalId\":7654,\"journal\":{\"name\":\"American journal of diseases of children\",\"volume\":\"8 1\",\"pages\":\"808-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"47\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of diseases of children\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1001/ARCHPEDI.1991.02160070104030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of diseases of children","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1001/ARCHPEDI.1991.02160070104030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Neutropenia in an extremely premature infant treated with recombinant human granulocyte colony-stimulating factor.
Neutropenia in the newborn is often associated with sepsis, maternal hypertension, or prematurity. We describe a 654-g infant born at 30 weeks' gestation by cesarean section due to severe maternal hypertension. His course was complicated by five episodes of sepsis, including three with group B streptococcus. The results of hematologic and immunologic studies were normal except that absolute neutrophil counts were low (less than 1 x 10(9)/L) with intermittent increases during sepsis. Human recombinant granulocyte colony-stimulating factor administered subcutaneously (10 micrograms/kg per day initially) resulted in an absolute neutrophil count of greater than 30 x 10(9)/L within 2 weeks. The dosage was lowered and the absolute neutrophil counts were maintained at 8 to 12 x 10(9)/L with no further septic episodes. The human recombinant granulocyte colony-stimulating factor therapy was discontinued after 7 months, and the patient remained healthy with an absolute neutrophil count of greater than 2 x 10(9)/L. Thus, treatment with human recombinant granulocyte colony-stimulating factor may be useful as a temporary measure for neonatal neutropenia associated with sepsis. A controlled, clinical trial is warranted.