{"title":"一家制革公司的能源审计与管理:以卡诺州为例","authors":"Jamilu Ya’u Muhammad, S. Alhassan, I. Abdulmajeed, N. H. Waziri, Najib x Hassan Waziri, Faru Faruk Tukur","doi":"10.11648/J.EPES.20200901.11","DOIUrl":null,"url":null,"abstract":"Energy audit is considered as one of the comprehensive methods in checking the energy usage and wastage in facilities/buildings. This paper presents the results of the energy audit conducted to investigate the energy consumption pattern of tannery company from its record of fuel expenditure and electricity bills for a period of 5 years (2012 - 2016). Also, the use of energy models system, Energy Quick Energy Simulation Tool (eQUEST) to evaluate the consumption of the energy end users and performance of the company. Results shows peak electricity demand during the hot months from April to August due to high cooling or significant Air condition requirement. 2.37% of electricity consumed was contributed by the burning of AGO in the diesel power generators showing very less contribution over that of National grid 97.63%. The annual average consumption demand of electricity and diesel (kWh equivalent) of the company were 118960.72 kWh and 2881.17 kWh respectively. The energy modeling and simulation results shows that the sum total of the total monthly energy consumption by the end users is 138164 kWh representing the total average value of the annual energy use in air-conditioning (space cooling) was 27%, ventilation fan 2%, factory machineries 39%, heat rejection is 4%, pump and auxiliary is 2% and area lighting 26%. Also, the total monthly peak demand by space cooling was 22372.2 kWh, ventilation fan 1376 kWh, factory machineries 14294kWh heat rejection is 4461 kWh, pump and auxiliary is 1343 kWh and area light 11023 kWh respectively having a sum total monthly peak demand by the end users to be 44969.2 kWh. This represent energy use in air-conditioning (space cooling) was 41%, ventilation fan 3%, 26% factory machineries, heat rejection is 8%, pump and auxiliary is 2% and 20% area light of the annual peak demand. The Energy Used Index (average annual electricity use per tones of leather) was found to be 717.38kWh/tones of leather/Annum.","PeriodicalId":43153,"journal":{"name":"International Journal of Power and Energy Systems","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2020-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Energy Audit and Management of a Tannery Company: A Case Study of Kano State\",\"authors\":\"Jamilu Ya’u Muhammad, S. Alhassan, I. Abdulmajeed, N. H. Waziri, Najib x Hassan Waziri, Faru Faruk Tukur\",\"doi\":\"10.11648/J.EPES.20200901.11\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Energy audit is considered as one of the comprehensive methods in checking the energy usage and wastage in facilities/buildings. This paper presents the results of the energy audit conducted to investigate the energy consumption pattern of tannery company from its record of fuel expenditure and electricity bills for a period of 5 years (2012 - 2016). Also, the use of energy models system, Energy Quick Energy Simulation Tool (eQUEST) to evaluate the consumption of the energy end users and performance of the company. Results shows peak electricity demand during the hot months from April to August due to high cooling or significant Air condition requirement. 2.37% of electricity consumed was contributed by the burning of AGO in the diesel power generators showing very less contribution over that of National grid 97.63%. The annual average consumption demand of electricity and diesel (kWh equivalent) of the company were 118960.72 kWh and 2881.17 kWh respectively. The energy modeling and simulation results shows that the sum total of the total monthly energy consumption by the end users is 138164 kWh representing the total average value of the annual energy use in air-conditioning (space cooling) was 27%, ventilation fan 2%, factory machineries 39%, heat rejection is 4%, pump and auxiliary is 2% and area lighting 26%. Also, the total monthly peak demand by space cooling was 22372.2 kWh, ventilation fan 1376 kWh, factory machineries 14294kWh heat rejection is 4461 kWh, pump and auxiliary is 1343 kWh and area light 11023 kWh respectively having a sum total monthly peak demand by the end users to be 44969.2 kWh. This represent energy use in air-conditioning (space cooling) was 41%, ventilation fan 3%, 26% factory machineries, heat rejection is 8%, pump and auxiliary is 2% and 20% area light of the annual peak demand. The Energy Used Index (average annual electricity use per tones of leather) was found to be 717.38kWh/tones of leather/Annum.\",\"PeriodicalId\":43153,\"journal\":{\"name\":\"International Journal of Power and Energy Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2020-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Power and Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11648/J.EPES.20200901.11\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Power and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11648/J.EPES.20200901.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 1

摘要

能源审计被认为是检查设施/建筑物的能源使用和浪费的综合方法之一。本文介绍了能源审计的结果,该审计旨在调查制革公司5年(2012年至2016年)的燃料支出和电费记录中的能源消耗模式。此外,使用能源模型系统,能源快速能源仿真工具(eQUEST)来评估最终用户的能源消耗和公司的绩效。结果显示,4月至8月的炎热月份,由于制冷或空调需求较高,电力需求达到峰值。柴油发电机组燃烧AGO占总耗电量的2.37%,远低于国家电网的97.63%。公司年平均用电需求为118960.72千瓦时,年平均用电需求为2881.17千瓦时。能源建模和仿真结果表明,最终用户每月总能耗为138164千瓦时,其中空调(空间冷却)年能耗的总平均值为27%,通风机为2%,工厂机械为39%,散热为4%,泵及辅助为2%,区域照明为26%。此外,空间制冷的月总峰值需求为22372.2 kWh,通风机为1376 kWh,工厂机械为14294kWh,排热为4461 kWh,泵及辅助为1343 kWh,区域灯为11023 kWh,最终用户的月总峰值需求为44969.2 kWh。这代表空调(空间冷却)的能源使用量为41%,通风机为3%,工厂机械为26%,散热为8%,泵和辅助为2%,区域照明为20%的年度高峰需求。能源使用指数(每吨皮革的年平均用电量)为717.38千瓦时/吨皮革/年。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Energy Audit and Management of a Tannery Company: A Case Study of Kano State
Energy audit is considered as one of the comprehensive methods in checking the energy usage and wastage in facilities/buildings. This paper presents the results of the energy audit conducted to investigate the energy consumption pattern of tannery company from its record of fuel expenditure and electricity bills for a period of 5 years (2012 - 2016). Also, the use of energy models system, Energy Quick Energy Simulation Tool (eQUEST) to evaluate the consumption of the energy end users and performance of the company. Results shows peak electricity demand during the hot months from April to August due to high cooling or significant Air condition requirement. 2.37% of electricity consumed was contributed by the burning of AGO in the diesel power generators showing very less contribution over that of National grid 97.63%. The annual average consumption demand of electricity and diesel (kWh equivalent) of the company were 118960.72 kWh and 2881.17 kWh respectively. The energy modeling and simulation results shows that the sum total of the total monthly energy consumption by the end users is 138164 kWh representing the total average value of the annual energy use in air-conditioning (space cooling) was 27%, ventilation fan 2%, factory machineries 39%, heat rejection is 4%, pump and auxiliary is 2% and area lighting 26%. Also, the total monthly peak demand by space cooling was 22372.2 kWh, ventilation fan 1376 kWh, factory machineries 14294kWh heat rejection is 4461 kWh, pump and auxiliary is 1343 kWh and area light 11023 kWh respectively having a sum total monthly peak demand by the end users to be 44969.2 kWh. This represent energy use in air-conditioning (space cooling) was 41%, ventilation fan 3%, 26% factory machineries, heat rejection is 8%, pump and auxiliary is 2% and 20% area light of the annual peak demand. The Energy Used Index (average annual electricity use per tones of leather) was found to be 717.38kWh/tones of leather/Annum.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Power and Energy Systems
International Journal of Power and Energy Systems ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
1.00
自引率
0.00%
发文量
5
期刊介绍: First published in 1972, this journal serves a worldwide readership of power and energy professionals. As one of the premier referred publications in the field, this journal strives to be the first to explore emerging energy issues, featuring only papers of the highest scientific merit. The subject areas of this journal include power transmission, distribution and generation, electric power quality, education, energy development, competition and regulation, power electronics, communication, electric machinery, power engineering systems, protection, reliability and security, energy management systems and supervisory control, economics, dispatching and scheduling, energy systems modelling and simulation, alternative energy sources, policy and planning.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信