{"title":"柔性电极等离子体发生器杀菌效果的研究","authors":"lee hyeok jae, Song Hyeonje","doi":"10.4313/JKEM.2020.33.1.70","DOIUrl":null,"url":null,"abstract":"In this study, the sterilization property of E. coli was established using a plasma generator with a flexible electrode structure. The bacterial suspension was prepared based on the McFarland standard 0.50 (1.5×10 CFU/mL) concentration and a specific amount was inoculated on the plate medium. After the plasma was discharged 3 cm away from the plasma generator in the range of 30s to 5 min and the results compared to the control group, the observed colonies that were formed decreased significantly as the plasma discharge time increased.","PeriodicalId":17325,"journal":{"name":"Journal of The Korean Institute of Electrical and Electronic Material Engineers","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A Study on the Effect of Microbial Sterilization Using Plasma Generator with a Flexible Electrodes Structure\",\"authors\":\"lee hyeok jae, Song Hyeonje\",\"doi\":\"10.4313/JKEM.2020.33.1.70\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, the sterilization property of E. coli was established using a plasma generator with a flexible electrode structure. The bacterial suspension was prepared based on the McFarland standard 0.50 (1.5×10 CFU/mL) concentration and a specific amount was inoculated on the plate medium. After the plasma was discharged 3 cm away from the plasma generator in the range of 30s to 5 min and the results compared to the control group, the observed colonies that were formed decreased significantly as the plasma discharge time increased.\",\"PeriodicalId\":17325,\"journal\":{\"name\":\"Journal of The Korean Institute of Electrical and Electronic Material Engineers\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Korean Institute of Electrical and Electronic Material Engineers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4313/JKEM.2020.33.1.70\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Korean Institute of Electrical and Electronic Material Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4313/JKEM.2020.33.1.70","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Study on the Effect of Microbial Sterilization Using Plasma Generator with a Flexible Electrodes Structure
In this study, the sterilization property of E. coli was established using a plasma generator with a flexible electrode structure. The bacterial suspension was prepared based on the McFarland standard 0.50 (1.5×10 CFU/mL) concentration and a specific amount was inoculated on the plate medium. After the plasma was discharged 3 cm away from the plasma generator in the range of 30s to 5 min and the results compared to the control group, the observed colonies that were formed decreased significantly as the plasma discharge time increased.