M. Caruso, V. Castiglia, A. Del Pizzo, R. Miceli, M. Salles, G. Schettino, V. Traversa, F. Viola
{"title":"基于atmega328p - pu单片机的低成本智能能源管理","authors":"M. Caruso, V. Castiglia, A. Del Pizzo, R. Miceli, M. Salles, G. Schettino, V. Traversa, F. Viola","doi":"10.1109/DISTRA.2017.8191244","DOIUrl":null,"url":null,"abstract":"This paper presents a real-time, low-cost, wireless, AC and DC monitoring system based on an ATmega328P-PU microcontroller. The proposed system is composed by different client nodes, which have the task to measure the main electrical quantities involved in the system, and a server node that collects the data and send them to a display device. The system is well suited for a good accuracy monitoring of either AC or DC electrical quantities. In order to verify the correct operation of the system, a case study for the simultaneous monitoring of the DC and AC voltages and currents is provided.","PeriodicalId":6535,"journal":{"name":"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"37 1","pages":"1204-1209"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Low-cost smart energy managment based on ATmega 328P-PU microcontroller\",\"authors\":\"M. Caruso, V. Castiglia, A. Del Pizzo, R. Miceli, M. Salles, G. Schettino, V. Traversa, F. Viola\",\"doi\":\"10.1109/DISTRA.2017.8191244\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a real-time, low-cost, wireless, AC and DC monitoring system based on an ATmega328P-PU microcontroller. The proposed system is composed by different client nodes, which have the task to measure the main electrical quantities involved in the system, and a server node that collects the data and send them to a display device. The system is well suited for a good accuracy monitoring of either AC or DC electrical quantities. In order to verify the correct operation of the system, a case study for the simultaneous monitoring of the DC and AC voltages and currents is provided.\",\"PeriodicalId\":6535,\"journal\":{\"name\":\"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)\",\"volume\":\"37 1\",\"pages\":\"1204-1209\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DISTRA.2017.8191244\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DISTRA.2017.8191244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Low-cost smart energy managment based on ATmega 328P-PU microcontroller
This paper presents a real-time, low-cost, wireless, AC and DC monitoring system based on an ATmega328P-PU microcontroller. The proposed system is composed by different client nodes, which have the task to measure the main electrical quantities involved in the system, and a server node that collects the data and send them to a display device. The system is well suited for a good accuracy monitoring of either AC or DC electrical quantities. In order to verify the correct operation of the system, a case study for the simultaneous monitoring of the DC and AC voltages and currents is provided.