考虑位置识别技术的高渗透可再生能源发电系统PMSG风电机组频率调节

R. Prasad, M. V. Gururaj, N. Padhy
{"title":"考虑位置识别技术的高渗透可再生能源发电系统PMSG风电机组频率调节","authors":"R. Prasad, M. V. Gururaj, N. Padhy","doi":"10.1109/PESGRE52268.2022.9715863","DOIUrl":null,"url":null,"abstract":"Frequency regulation participation of the permanent magnet synchronous generator (PMSG) wind turbine (WT) is rigorously practiced nowadays with the increasing penetration of renewable generation in the generation mix. In line with the objective, a novel location identified frequency control (LIFC) is proposed by the authors, that select locationally targeted remedial frequency control measures in a decentralized manner and does not depend on system-wise observability. The first component of the LIFC is an attuned power balance factor (APBF) which takes the tie line power into consideration for quick response by the PMSG for enhanced load frequency control (En-LFC). The second term of LIFC is the inertial and primary frequency control loop, and act on the frequency variation over time in the dynamically changing power system. The real-time simulation result shows that the performance of LIFC is fast in action and provides overall frequency support to the grid at the time of frequency events.","PeriodicalId":64562,"journal":{"name":"智能电网与可再生能源(英文)","volume":"1 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Frequency Regulation of PMSG Based Wind Turbine Considering Location Identification Technique in High Penetration of Renewable Generation System\",\"authors\":\"R. Prasad, M. V. Gururaj, N. Padhy\",\"doi\":\"10.1109/PESGRE52268.2022.9715863\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Frequency regulation participation of the permanent magnet synchronous generator (PMSG) wind turbine (WT) is rigorously practiced nowadays with the increasing penetration of renewable generation in the generation mix. In line with the objective, a novel location identified frequency control (LIFC) is proposed by the authors, that select locationally targeted remedial frequency control measures in a decentralized manner and does not depend on system-wise observability. The first component of the LIFC is an attuned power balance factor (APBF) which takes the tie line power into consideration for quick response by the PMSG for enhanced load frequency control (En-LFC). The second term of LIFC is the inertial and primary frequency control loop, and act on the frequency variation over time in the dynamically changing power system. The real-time simulation result shows that the performance of LIFC is fast in action and provides overall frequency support to the grid at the time of frequency events.\",\"PeriodicalId\":64562,\"journal\":{\"name\":\"智能电网与可再生能源(英文)\",\"volume\":\"1 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"智能电网与可再生能源(英文)\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGRE52268.2022.9715863\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"智能电网与可再生能源(英文)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.1109/PESGRE52268.2022.9715863","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着可再生能源发电在发电结构中的比重越来越大,永磁同步发电机(PMSG)风力发电机组(WT)的频率调节参与也越来越严格。根据目标,作者提出了一种新的位置识别频率控制(LIFC),它以分散的方式选择定位的补救频率控制措施,并且不依赖于系统的可观测性。LIFC的第一个组成部分是一个调谐的功率平衡因子(APBF),它考虑了PMSG对增强负载频率控制(En-LFC)的快速响应的tie线功率。LIFC的第二项是惯性和一次频率控制环,在动态变化的电力系统中作用于频率随时间的变化。实时仿真结果表明,LIFC的运行速度快,在频率事件发生时为电网提供全面的频率支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Frequency Regulation of PMSG Based Wind Turbine Considering Location Identification Technique in High Penetration of Renewable Generation System
Frequency regulation participation of the permanent magnet synchronous generator (PMSG) wind turbine (WT) is rigorously practiced nowadays with the increasing penetration of renewable generation in the generation mix. In line with the objective, a novel location identified frequency control (LIFC) is proposed by the authors, that select locationally targeted remedial frequency control measures in a decentralized manner and does not depend on system-wise observability. The first component of the LIFC is an attuned power balance factor (APBF) which takes the tie line power into consideration for quick response by the PMSG for enhanced load frequency control (En-LFC). The second term of LIFC is the inertial and primary frequency control loop, and act on the frequency variation over time in the dynamically changing power system. The real-time simulation result shows that the performance of LIFC is fast in action and provides overall frequency support to the grid at the time of frequency events.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
307
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信