{"title":"单相有源电力滤波器的H/sub /spl输入//控制:一种系统方法","authors":"P. Chevrel, F. Auger, M. Machmoum","doi":"10.1109/PESC.1996.548721","DOIUrl":null,"url":null,"abstract":"This paper shows the efficiency of the H/sub /spl infin// control design methodology for the case of the active filtering of single phase power networks. At first, a continuous time H/sub /spl infin// controller is designed which achieves all performances and robustness properties required. In particular, this approach allows one to choose the attenuation of each harmonic frequency independently of each other. Finally an effective 18th order discrete regulator is derived from the continuous one in an original way.","PeriodicalId":19979,"journal":{"name":"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference","volume":"22 1","pages":"1112-1118 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1996-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"H/sub /spl infin// control for a single-phase active power filter: a systematic approach\",\"authors\":\"P. Chevrel, F. Auger, M. Machmoum\",\"doi\":\"10.1109/PESC.1996.548721\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper shows the efficiency of the H/sub /spl infin// control design methodology for the case of the active filtering of single phase power networks. At first, a continuous time H/sub /spl infin// controller is designed which achieves all performances and robustness properties required. In particular, this approach allows one to choose the attenuation of each harmonic frequency independently of each other. Finally an effective 18th order discrete regulator is derived from the continuous one in an original way.\",\"PeriodicalId\":19979,\"journal\":{\"name\":\"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"22 1\",\"pages\":\"1112-1118 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1996.548721\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1996.548721","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
H/sub /spl infin// control for a single-phase active power filter: a systematic approach
This paper shows the efficiency of the H/sub /spl infin// control design methodology for the case of the active filtering of single phase power networks. At first, a continuous time H/sub /spl infin// controller is designed which achieves all performances and robustness properties required. In particular, this approach allows one to choose the attenuation of each harmonic frequency independently of each other. Finally an effective 18th order discrete regulator is derived from the continuous one in an original way.