心房颤动的诱发性混沌地依赖于离子模型参数

M. Potse
{"title":"心房颤动的诱发性混沌地依赖于离子模型参数","authors":"M. Potse","doi":"10.23919/CinC49843.2019.9005889","DOIUrl":null,"url":null,"abstract":"Previous work has shown that fibrillation can be induced by rapid pacing in a model of the human atria without fibrosis or repolarization heterogeneity. The purpose of this study was to investigate how sensitive this type of arrhythmia induction is to model parameters.Simulations were performed with a monodomain reaction-diffusion model with Courtemanche dynamics on a volumetric atrial mesh with all the major bundle structures and layered fiber orientation. The ionic model parameters were modified to represent electrically remodeled atria, uniformly. The model was stimulated with decreasing cycle length to drive the atria to maximum rate, and simulated over 10 seconds. This was tried with 10 different pacing locations and 46 different values of the conductivity, gCaL, of the L-type calcium current.For gCaL values up to 130% of the initial value, on average 4 out of 10 pacing sites induced AF. However, the positive sites were different for each tested gCaL level, even at 1% increments. Beyond 130%, the AF induction rate decreased. Every pacing site yielded AF for a subset of parameter values, but some sites more frequently.In conclusion, AF induction is highly sensitive to parameter values. The global decrease in induction seen for large gCaL may be due to the increased wavelength.","PeriodicalId":6697,"journal":{"name":"2019 Computing in Cardiology (CinC)","volume":"17 1","pages":"Page 1-Page 4"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Inducibility of Atrial Fibrillation Depends Chaotically on Ionic Model Parameters\",\"authors\":\"M. Potse\",\"doi\":\"10.23919/CinC49843.2019.9005889\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Previous work has shown that fibrillation can be induced by rapid pacing in a model of the human atria without fibrosis or repolarization heterogeneity. The purpose of this study was to investigate how sensitive this type of arrhythmia induction is to model parameters.Simulations were performed with a monodomain reaction-diffusion model with Courtemanche dynamics on a volumetric atrial mesh with all the major bundle structures and layered fiber orientation. The ionic model parameters were modified to represent electrically remodeled atria, uniformly. The model was stimulated with decreasing cycle length to drive the atria to maximum rate, and simulated over 10 seconds. This was tried with 10 different pacing locations and 46 different values of the conductivity, gCaL, of the L-type calcium current.For gCaL values up to 130% of the initial value, on average 4 out of 10 pacing sites induced AF. However, the positive sites were different for each tested gCaL level, even at 1% increments. Beyond 130%, the AF induction rate decreased. Every pacing site yielded AF for a subset of parameter values, but some sites more frequently.In conclusion, AF induction is highly sensitive to parameter values. The global decrease in induction seen for large gCaL may be due to the increased wavelength.\",\"PeriodicalId\":6697,\"journal\":{\"name\":\"2019 Computing in Cardiology (CinC)\",\"volume\":\"17 1\",\"pages\":\"Page 1-Page 4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 Computing in Cardiology (CinC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/CinC49843.2019.9005889\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/CinC49843.2019.9005889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

先前的研究表明,在没有纤维化或复极化异质性的人类心房模型中,快速起搏可诱导心房颤动。本研究的目的是探讨这种类型的心律失常诱导对模型参数的敏感性。在具有所有主要束结构和层状纤维取向的容积式心房网上,采用具有Courtemanche动力学的单域反应扩散模型进行了模拟。离子模型参数被修改,以均匀地表示电重构的心房。通过减小循环长度刺激心房达到最大速率,模拟时间超过10秒。在10个不同的起搏位置和46个不同的l型钙电流电导率gCaL值下进行了试验。当gCaL值达到初始值的130%时,平均10个起搏位点中有4个诱发心房颤动。然而,即使在gCaL水平增加1%时,每个检测的阳性位点也是不同的。超过130%,AF诱导率下降。每个起搏点产生AF参数值的子集,但有些点更频繁。综上所述,AF感应对参数值高度敏感。对于大gCaL,感应强度的整体下降可能是由于波长增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inducibility of Atrial Fibrillation Depends Chaotically on Ionic Model Parameters
Previous work has shown that fibrillation can be induced by rapid pacing in a model of the human atria without fibrosis or repolarization heterogeneity. The purpose of this study was to investigate how sensitive this type of arrhythmia induction is to model parameters.Simulations were performed with a monodomain reaction-diffusion model with Courtemanche dynamics on a volumetric atrial mesh with all the major bundle structures and layered fiber orientation. The ionic model parameters were modified to represent electrically remodeled atria, uniformly. The model was stimulated with decreasing cycle length to drive the atria to maximum rate, and simulated over 10 seconds. This was tried with 10 different pacing locations and 46 different values of the conductivity, gCaL, of the L-type calcium current.For gCaL values up to 130% of the initial value, on average 4 out of 10 pacing sites induced AF. However, the positive sites were different for each tested gCaL level, even at 1% increments. Beyond 130%, the AF induction rate decreased. Every pacing site yielded AF for a subset of parameter values, but some sites more frequently.In conclusion, AF induction is highly sensitive to parameter values. The global decrease in induction seen for large gCaL may be due to the increased wavelength.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信