{"title":"AgNO3溶液对碘和有机碘化物去除率的评价","authors":"T. Kanai, M. Furuya, S. Nisimura","doi":"10.3327/taesj.j18.034","DOIUrl":null,"url":null,"abstract":"When excess pressure and temperature are added to a containment vessel of a nuclear power plant during a severe accident, damage of the containment vessel and the release of radioactive materials into the environment are expected. Filtered containment venting systems (FCVS) installed in exhaust systems reduce the release of radioactive materials by the use of multistage filters. In actual FCVS, several types of alkaline solution are used in the scrubbing stage to capture the radioactive iodine (I2). Therefore, it is difficult to remove CH3I by the alkaline solution, and molecular sieves such as silver zeolites installed downstream of the scrubbing stage are used to capture the organic iodide (CH3I). Silver nitrate aqueous solution (AgNO3 aq.) is highly reactive against iodine; hence, by using AgNO3 aq., the removal of organic iodide in the scrubbing stage can be expected. We have conducted basic evaluations of the removal properties of iodine and organic iodide by AgNO3 aq. using smallscale and pool-scrubbing (inner diameter: 300 mm) test sections at ambient temperature and pressure. The small-scale test results show that AgNO3 aq. has the same I2 removal performance as sodium hydroxide aqueous solution (NaOH aq.). Moreover, the pool-scrubbing test results show that a CH3I decontamination factor (DF) of over 50 can be expected under the conditions of a AgNO3 concentration ≥ 10 wt% and submergence ≥ 1.14 m.","PeriodicalId":8595,"journal":{"name":"Atomic Energy Society of Japan","volume":"95 1","pages":"16-23"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Removal Properties of Iodine and Organic Iodide by a AgNO3 Solution\",\"authors\":\"T. Kanai, M. Furuya, S. Nisimura\",\"doi\":\"10.3327/taesj.j18.034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When excess pressure and temperature are added to a containment vessel of a nuclear power plant during a severe accident, damage of the containment vessel and the release of radioactive materials into the environment are expected. Filtered containment venting systems (FCVS) installed in exhaust systems reduce the release of radioactive materials by the use of multistage filters. In actual FCVS, several types of alkaline solution are used in the scrubbing stage to capture the radioactive iodine (I2). Therefore, it is difficult to remove CH3I by the alkaline solution, and molecular sieves such as silver zeolites installed downstream of the scrubbing stage are used to capture the organic iodide (CH3I). Silver nitrate aqueous solution (AgNO3 aq.) is highly reactive against iodine; hence, by using AgNO3 aq., the removal of organic iodide in the scrubbing stage can be expected. We have conducted basic evaluations of the removal properties of iodine and organic iodide by AgNO3 aq. using smallscale and pool-scrubbing (inner diameter: 300 mm) test sections at ambient temperature and pressure. The small-scale test results show that AgNO3 aq. has the same I2 removal performance as sodium hydroxide aqueous solution (NaOH aq.). Moreover, the pool-scrubbing test results show that a CH3I decontamination factor (DF) of over 50 can be expected under the conditions of a AgNO3 concentration ≥ 10 wt% and submergence ≥ 1.14 m.\",\"PeriodicalId\":8595,\"journal\":{\"name\":\"Atomic Energy Society of Japan\",\"volume\":\"95 1\",\"pages\":\"16-23\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atomic Energy Society of Japan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3327/taesj.j18.034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atomic Energy Society of Japan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3327/taesj.j18.034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of the Removal Properties of Iodine and Organic Iodide by a AgNO3 Solution
When excess pressure and temperature are added to a containment vessel of a nuclear power plant during a severe accident, damage of the containment vessel and the release of radioactive materials into the environment are expected. Filtered containment venting systems (FCVS) installed in exhaust systems reduce the release of radioactive materials by the use of multistage filters. In actual FCVS, several types of alkaline solution are used in the scrubbing stage to capture the radioactive iodine (I2). Therefore, it is difficult to remove CH3I by the alkaline solution, and molecular sieves such as silver zeolites installed downstream of the scrubbing stage are used to capture the organic iodide (CH3I). Silver nitrate aqueous solution (AgNO3 aq.) is highly reactive against iodine; hence, by using AgNO3 aq., the removal of organic iodide in the scrubbing stage can be expected. We have conducted basic evaluations of the removal properties of iodine and organic iodide by AgNO3 aq. using smallscale and pool-scrubbing (inner diameter: 300 mm) test sections at ambient temperature and pressure. The small-scale test results show that AgNO3 aq. has the same I2 removal performance as sodium hydroxide aqueous solution (NaOH aq.). Moreover, the pool-scrubbing test results show that a CH3I decontamination factor (DF) of over 50 can be expected under the conditions of a AgNO3 concentration ≥ 10 wt% and submergence ≥ 1.14 m.