HgI2剂量测定

C. Manfredotti
{"title":"HgI2剂量测定","authors":"C. Manfredotti","doi":"10.1016/0167-5087(84)91355-3","DOIUrl":null,"url":null,"abstract":"<div><p>The possibility of using HgI<sub>2</sub> as a survey dosimeter with a tissue-equivalent response in the energy range 1 keV to 1 MeV is theoretically investigated and discussed. The response function of HgI<sub>2</sub> is evaluated and checked with experimental data. HgI<sub>2</sub> with an energy threshold, in the counting mode, can have a reasonable tissue-equivalent response in the range 100–600 keV with a minimum detectable exposure rate of about 20 μR/h.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 1","pages":"Pages 173-178"},"PeriodicalIF":0.0000,"publicationDate":"1984-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)91355-3","citationCount":"2","resultStr":"{\"title\":\"Dosimetry with HgI2\",\"authors\":\"C. Manfredotti\",\"doi\":\"10.1016/0167-5087(84)91355-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The possibility of using HgI<sub>2</sub> as a survey dosimeter with a tissue-equivalent response in the energy range 1 keV to 1 MeV is theoretically investigated and discussed. The response function of HgI<sub>2</sub> is evaluated and checked with experimental data. HgI<sub>2</sub> with an energy threshold, in the counting mode, can have a reasonable tissue-equivalent response in the range 100–600 keV with a minimum detectable exposure rate of about 20 μR/h.</p></div>\",\"PeriodicalId\":100972,\"journal\":{\"name\":\"Nuclear Instruments and Methods in Physics Research\",\"volume\":\"225 1\",\"pages\":\"Pages 173-178\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1984-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0167-5087(84)91355-3\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods in Physics Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0167508784913553\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods in Physics Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0167508784913553","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

从理论上探讨了利用HgI2作为在1 keV ~ 1 MeV能量范围内具有组织等效响应的测量剂量计的可能性。用实验数据对HgI2的响应函数进行了评估和验证。在计数模式下,具有能量阈值的HgI2在100-600 keV范围内具有合理的组织等效响应,最小可检测暴露率约为20 μR/h。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dosimetry with HgI2

The possibility of using HgI2 as a survey dosimeter with a tissue-equivalent response in the energy range 1 keV to 1 MeV is theoretically investigated and discussed. The response function of HgI2 is evaluated and checked with experimental data. HgI2 with an energy threshold, in the counting mode, can have a reasonable tissue-equivalent response in the range 100–600 keV with a minimum detectable exposure rate of about 20 μR/h.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信