{"title":"利用微流体设计改进自供电葡萄糖生物传感器系统","authors":"R. Escalona-Villalpando, A. Sandoval-García, S. Minteer, L. Arriaga, J. Ledesma-García","doi":"10.1109/PowerMEMS49317.2019.61547413059","DOIUrl":null,"url":null,"abstract":"A self-powered glucose sensor (SPGS) system integrates a biofuel cell (BFC) as a power source for operation of a biosensor. SPGS uses glucose as an analyte to be quantified and as a fuel, since it’s a molecule of biomedical interest because it’s related to diabetes. Glucose oxidase electrode-based was used in the anode and laccase based-electrode was used in the cathode within a microfluidic device where different glucose concentrations between 0 and 10 mM were used. In the polarization and current curves were observed an increase at a higher glucose concentration, without altering its operation in the presence interferences. This result indicated an improvement in the performance of an SPGS by integrating a microfluidic device, increasing the stability, limit of detection, quantification, stability and sensitivity for the quantification of glucose through the operation of a BFC.","PeriodicalId":6648,"journal":{"name":"2019 19th International Conference on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS)","volume":"83 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improving a self-powered glucose biosensor system using a microfluidic design\",\"authors\":\"R. Escalona-Villalpando, A. Sandoval-García, S. Minteer, L. Arriaga, J. Ledesma-García\",\"doi\":\"10.1109/PowerMEMS49317.2019.61547413059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A self-powered glucose sensor (SPGS) system integrates a biofuel cell (BFC) as a power source for operation of a biosensor. SPGS uses glucose as an analyte to be quantified and as a fuel, since it’s a molecule of biomedical interest because it’s related to diabetes. Glucose oxidase electrode-based was used in the anode and laccase based-electrode was used in the cathode within a microfluidic device where different glucose concentrations between 0 and 10 mM were used. In the polarization and current curves were observed an increase at a higher glucose concentration, without altering its operation in the presence interferences. This result indicated an improvement in the performance of an SPGS by integrating a microfluidic device, increasing the stability, limit of detection, quantification, stability and sensitivity for the quantification of glucose through the operation of a BFC.\",\"PeriodicalId\":6648,\"journal\":{\"name\":\"2019 19th International Conference on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS)\",\"volume\":\"83 1\",\"pages\":\"1-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 19th International Conference on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PowerMEMS49317.2019.61547413059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 19th International Conference on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PowerMEMS49317.2019.61547413059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一种自供电葡萄糖传感器(SPGS)系统集成了生物燃料电池(BFC)作为生物传感器运行的电源。SPGS使用葡萄糖作为定量分析物和燃料,因为它是一种与糖尿病有关的生物医学分子。在微流控装置中,葡萄糖氧化酶电极为阳极,漆酶电极为阴极,葡萄糖浓度在0 ~ 10 mM之间。在极化和电流曲线中,观察到在较高的葡萄糖浓度下增加,而在存在干扰的情况下不改变其操作。该结果表明,通过集成微流体装置,SPGS的性能得到了改善,增加了稳定性、检出限、定量、稳定性和灵敏度,可以通过BFC操作来定量葡萄糖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improving a self-powered glucose biosensor system using a microfluidic design
A self-powered glucose sensor (SPGS) system integrates a biofuel cell (BFC) as a power source for operation of a biosensor. SPGS uses glucose as an analyte to be quantified and as a fuel, since it’s a molecule of biomedical interest because it’s related to diabetes. Glucose oxidase electrode-based was used in the anode and laccase based-electrode was used in the cathode within a microfluidic device where different glucose concentrations between 0 and 10 mM were used. In the polarization and current curves were observed an increase at a higher glucose concentration, without altering its operation in the presence interferences. This result indicated an improvement in the performance of an SPGS by integrating a microfluidic device, increasing the stability, limit of detection, quantification, stability and sensitivity for the quantification of glucose through the operation of a BFC.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信