Masaaki Kobayashi, Yoshio Yoshimura, Masami Chiba, Jun'ichiro Iwahori, Hajime Yoshida
{"title":"20 - 120mev电子闪烁玻璃淋浴探测器的性能","authors":"Masaaki Kobayashi, Yoshio Yoshimura, Masami Chiba, Jun'ichiro Iwahori, Hajime Yoshida","doi":"10.1016/0029-554X(81)90737-0","DOIUrl":null,"url":null,"abstract":"<div><p>A scintillator glass (type : SCG1B) detector of 14 × 14 × 40 cm<sup>3</sup> gives an energy resolution (fwhm) of <span><math><mtext>6.5%/E</mtext><msup><mi></mi><mn><mtext>−1</mtext><mtext>2</mtext></mn></msup></math></span> for low energy electrons, which is better than for lead glass by a factor approximately 0.6. The light yield for SCG1B is 3.4 times that for lead glass (SF5) if the blocks have similar dimensions. Different surface textures are also compared.</p></div>","PeriodicalId":100971,"journal":{"name":"Nuclear Instruments and Methods","volume":"184 2","pages":"Pages 399-404"},"PeriodicalIF":0.0000,"publicationDate":"1981-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0029-554X(81)90737-0","citationCount":"10","resultStr":"{\"title\":\"Performance of a scintillator glass shower detector for 20–120 MeV electrons\",\"authors\":\"Masaaki Kobayashi, Yoshio Yoshimura, Masami Chiba, Jun'ichiro Iwahori, Hajime Yoshida\",\"doi\":\"10.1016/0029-554X(81)90737-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A scintillator glass (type : SCG1B) detector of 14 × 14 × 40 cm<sup>3</sup> gives an energy resolution (fwhm) of <span><math><mtext>6.5%/E</mtext><msup><mi></mi><mn><mtext>−1</mtext><mtext>2</mtext></mn></msup></math></span> for low energy electrons, which is better than for lead glass by a factor approximately 0.6. The light yield for SCG1B is 3.4 times that for lead glass (SF5) if the blocks have similar dimensions. Different surface textures are also compared.</p></div>\",\"PeriodicalId\":100971,\"journal\":{\"name\":\"Nuclear Instruments and Methods\",\"volume\":\"184 2\",\"pages\":\"Pages 399-404\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0029-554X(81)90737-0\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0029554X81907370\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0029554X81907370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance of a scintillator glass shower detector for 20–120 MeV electrons
A scintillator glass (type : SCG1B) detector of 14 × 14 × 40 cm3 gives an energy resolution (fwhm) of for low energy electrons, which is better than for lead glass by a factor approximately 0.6. The light yield for SCG1B is 3.4 times that for lead glass (SF5) if the blocks have similar dimensions. Different surface textures are also compared.