活化加速器室混凝土去污方案及其实施——以医学与药理研究中心基金会PET回旋加速器室退役为例

Y. Miyazaki, G. Yoshida, K. Masumoto, H. Matsumura, Masahiro Tanaka
{"title":"活化加速器室混凝土去污方案及其实施——以医学与药理研究中心基金会PET回旋加速器室退役为例","authors":"Y. Miyazaki, G. Yoshida, K. Masumoto, H. Matsumura, Masahiro Tanaka","doi":"10.3769/radioisotopes.69.365","DOIUrl":null,"url":null,"abstract":"Herein, we present the case study of the decontamination of highly activated concrete in the accelerator room. The activated cyclotron room for pharmaceutical for the positron emission tomography (PET) in the Medical and Pharmacological Research Center Foundation (Ishikawa, Japan) was decontaminated. The contact dose rates of the concrete walls, floor, and ceiling were measured at 50 cm mesh using a NaI survey meter. The depth profiles of spe cific activity in the concretes were obtained by core boring at seven different places. The activated concrete regions were estimated in detail based on the relationship between the measured contact dose rates and depth profiles of the specific activity. The activated concrete was chipped and","PeriodicalId":20809,"journal":{"name":"Radioisotopes","volume":"34 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Decontamination Plan for the Concrete of the Activated Accelerator Room and Its Implementation: A Case Study in the Decommissioning of the PET Cyclotron Room at the Medical and Pharmacological Research Center Foundation\",\"authors\":\"Y. Miyazaki, G. Yoshida, K. Masumoto, H. Matsumura, Masahiro Tanaka\",\"doi\":\"10.3769/radioisotopes.69.365\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Herein, we present the case study of the decontamination of highly activated concrete in the accelerator room. The activated cyclotron room for pharmaceutical for the positron emission tomography (PET) in the Medical and Pharmacological Research Center Foundation (Ishikawa, Japan) was decontaminated. The contact dose rates of the concrete walls, floor, and ceiling were measured at 50 cm mesh using a NaI survey meter. The depth profiles of spe cific activity in the concretes were obtained by core boring at seven different places. The activated concrete regions were estimated in detail based on the relationship between the measured contact dose rates and depth profiles of the specific activity. The activated concrete was chipped and\",\"PeriodicalId\":20809,\"journal\":{\"name\":\"Radioisotopes\",\"volume\":\"34 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radioisotopes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3769/radioisotopes.69.365\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radioisotopes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3769/radioisotopes.69.365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在此,我们提出了高活性混凝土在加速器室去污的案例研究。对日本石川医学和药理学研究中心基金会正电子发射断层扫描(PET)制药用活化回旋加速器室进行了净化。用NaI测量仪在50 cm网孔处测量混凝土墙、地板和天花板的接触剂量率。通过在7个不同的地方钻孔,获得了混凝土中比活度的深度剖面。根据所测接触剂量率与比活性深度剖面之间的关系,对活化混凝土区域进行了详细估算。活化混凝土已经碎裂
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Decontamination Plan for the Concrete of the Activated Accelerator Room and Its Implementation: A Case Study in the Decommissioning of the PET Cyclotron Room at the Medical and Pharmacological Research Center Foundation
Herein, we present the case study of the decontamination of highly activated concrete in the accelerator room. The activated cyclotron room for pharmaceutical for the positron emission tomography (PET) in the Medical and Pharmacological Research Center Foundation (Ishikawa, Japan) was decontaminated. The contact dose rates of the concrete walls, floor, and ceiling were measured at 50 cm mesh using a NaI survey meter. The depth profiles of spe cific activity in the concretes were obtained by core boring at seven different places. The activated concrete regions were estimated in detail based on the relationship between the measured contact dose rates and depth profiles of the specific activity. The activated concrete was chipped and
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信