Ahmed A. Al-obedy, Ammar A. AL-Battawy, Omar K. Younus
{"title":"CR-39核径迹探测器体腐蚀速率随化学腐蚀溶液正态性的变化","authors":"Ahmed A. Al-obedy, Ammar A. AL-Battawy, Omar K. Younus","doi":"10.25130/tjps.v20i5.1250","DOIUrl":null,"url":null,"abstract":"The variation of the bulk etch rate (VB) of nuclear track detector CR-39 with the normality of the chemical etchant were studied. The removal thickness measurement method is used to determine the bulk etch rate. the detectors were etched by an aqueous solution of NaOH with normalities (4, 5, 6, 7) N at temperature (70±1) oC. It was found that the bulk etch rate is exponentially increasing with the normality of the solution and its values are (0.687, 1.421, 0.954, 2.082) µm/h at normalities (4, 5, 6, 7) N respectively. the relation between the bulk etch rate and the etchant normality was an exponential relation and the results showed good agreement with the results of the others used other normalities and another measurement method. \n ","PeriodicalId":23142,"journal":{"name":"Tikrit Journal of Pure Science","volume":"8 8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality\",\"authors\":\"Ahmed A. Al-obedy, Ammar A. AL-Battawy, Omar K. Younus\",\"doi\":\"10.25130/tjps.v20i5.1250\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The variation of the bulk etch rate (VB) of nuclear track detector CR-39 with the normality of the chemical etchant were studied. The removal thickness measurement method is used to determine the bulk etch rate. the detectors were etched by an aqueous solution of NaOH with normalities (4, 5, 6, 7) N at temperature (70±1) oC. It was found that the bulk etch rate is exponentially increasing with the normality of the solution and its values are (0.687, 1.421, 0.954, 2.082) µm/h at normalities (4, 5, 6, 7) N respectively. the relation between the bulk etch rate and the etchant normality was an exponential relation and the results showed good agreement with the results of the others used other normalities and another measurement method. \\n \",\"PeriodicalId\":23142,\"journal\":{\"name\":\"Tikrit Journal of Pure Science\",\"volume\":\"8 8 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tikrit Journal of Pure Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25130/tjps.v20i5.1250\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tikrit Journal of Pure Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25130/tjps.v20i5.1250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality
The variation of the bulk etch rate (VB) of nuclear track detector CR-39 with the normality of the chemical etchant were studied. The removal thickness measurement method is used to determine the bulk etch rate. the detectors were etched by an aqueous solution of NaOH with normalities (4, 5, 6, 7) N at temperature (70±1) oC. It was found that the bulk etch rate is exponentially increasing with the normality of the solution and its values are (0.687, 1.421, 0.954, 2.082) µm/h at normalities (4, 5, 6, 7) N respectively. the relation between the bulk etch rate and the etchant normality was an exponential relation and the results showed good agreement with the results of the others used other normalities and another measurement method.