一个新的校准概念的脉冲电声方法允许改进电荷密度测量

M. Arnaout, F. Baudoin, L. Berquez, D. Payan
{"title":"一个新的校准概念的脉冲电声方法允许改进电荷密度测量","authors":"M. Arnaout, F. Baudoin, L. Berquez, D. Payan","doi":"10.1109/CEIDP.2011.6232643","DOIUrl":null,"url":null,"abstract":"This work is focused on the improvement of the calibration technique in order to obtain a well-conditioned transfer matrix in a Pulsed Electro-Acoustic -PEA- cell. A numerical electro-acoustic model has been developed with software Comsol. Using this model, we can establish the output voltage of the piezoelectric sensor and acoustic pressure at each point of the calculation domain. Our approach consists to recover charge distribution within the sample using deconvolution method and transfer matrix obtained with the new calibration technique. This new method has been tested with theoretical and experimental signals. The main conclusion is that an improvement of the spatial resolution is demonstrated, compared to the standard method usually used.","PeriodicalId":6317,"journal":{"name":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"28 1","pages":"247-250"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A new calibration concept of the Pulsed Electro Acoustic method allowing to improve charge density measurement\",\"authors\":\"M. Arnaout, F. Baudoin, L. Berquez, D. Payan\",\"doi\":\"10.1109/CEIDP.2011.6232643\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work is focused on the improvement of the calibration technique in order to obtain a well-conditioned transfer matrix in a Pulsed Electro-Acoustic -PEA- cell. A numerical electro-acoustic model has been developed with software Comsol. Using this model, we can establish the output voltage of the piezoelectric sensor and acoustic pressure at each point of the calculation domain. Our approach consists to recover charge distribution within the sample using deconvolution method and transfer matrix obtained with the new calibration technique. This new method has been tested with theoretical and experimental signals. The main conclusion is that an improvement of the spatial resolution is demonstrated, compared to the standard method usually used.\",\"PeriodicalId\":6317,\"journal\":{\"name\":\"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"28 1\",\"pages\":\"247-250\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2011.6232643\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2011.6232643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文的工作重点是改进校准技术,以便在脉冲电声- pea -细胞中获得条件良好的传递矩阵。利用Comsol软件建立了一个数值电声模型。利用该模型,可以建立计算域内各点的压电传感器输出电压和声压。我们的方法包括利用反褶积方法和利用新校准技术获得的传递矩阵来恢复样品内的电荷分布。这种新方法已经用理论和实验信号进行了验证。主要结论是,与通常使用的标准方法相比,证明了空间分辨率的提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new calibration concept of the Pulsed Electro Acoustic method allowing to improve charge density measurement
This work is focused on the improvement of the calibration technique in order to obtain a well-conditioned transfer matrix in a Pulsed Electro-Acoustic -PEA- cell. A numerical electro-acoustic model has been developed with software Comsol. Using this model, we can establish the output voltage of the piezoelectric sensor and acoustic pressure at each point of the calculation domain. Our approach consists to recover charge distribution within the sample using deconvolution method and transfer matrix obtained with the new calibration technique. This new method has been tested with theoretical and experimental signals. The main conclusion is that an improvement of the spatial resolution is demonstrated, compared to the standard method usually used.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信