{"title":"3马力离心泵型性能试验","authors":"Wasiran Wasiran, W. D. Yudisworo, Endang Prihastuty","doi":"10.47685/mestro.v5i02.365","DOIUrl":null,"url":null,"abstract":"Pumps are fluid machines whose uses are very broad and important, ranging from industry to household needs. Selection of pump performance characteristics is very important and must be adjusted to the needs which include: discharge, head, power, and rotation. The performance characteristics of the pump are obtained through testing. In connection with the importance of information about pump performance characteristics, through this research activity efforts will be made to test centrifugal pumps using 3 hp of power. In this research, the data obtained from the direct test results will be entered, where the test is carried out at the Machine Performance Test Laboratory. In this test, the pump pressure data obtained from the gauge gradually with several valve openings, then the data is entered into the data table that has been prepared. The test was carried out to test the ability of the centrifugal pump test equipment using 3 HP power which was prepared as one of the laboratory pump test equipment for engine performance testing. In testing the centrifugal pump there are 3 variables that will be used to carry out the test, namely the first by using a tachometer which is useful for measuring shaft rotation, the second by using a Bordoun manometer which is useful for measuring fluid pressure, the third by using an orifice which functions to measure speed fluid.","PeriodicalId":31717,"journal":{"name":"Simetris Jurnal Teknik Mesin Elektro dan Ilmu Komputer","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance Testing of Centrifugal Pump Type with 3 Hp Power\",\"authors\":\"Wasiran Wasiran, W. D. Yudisworo, Endang Prihastuty\",\"doi\":\"10.47685/mestro.v5i02.365\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pumps are fluid machines whose uses are very broad and important, ranging from industry to household needs. Selection of pump performance characteristics is very important and must be adjusted to the needs which include: discharge, head, power, and rotation. The performance characteristics of the pump are obtained through testing. In connection with the importance of information about pump performance characteristics, through this research activity efforts will be made to test centrifugal pumps using 3 hp of power. In this research, the data obtained from the direct test results will be entered, where the test is carried out at the Machine Performance Test Laboratory. In this test, the pump pressure data obtained from the gauge gradually with several valve openings, then the data is entered into the data table that has been prepared. The test was carried out to test the ability of the centrifugal pump test equipment using 3 HP power which was prepared as one of the laboratory pump test equipment for engine performance testing. In testing the centrifugal pump there are 3 variables that will be used to carry out the test, namely the first by using a tachometer which is useful for measuring shaft rotation, the second by using a Bordoun manometer which is useful for measuring fluid pressure, the third by using an orifice which functions to measure speed fluid.\",\"PeriodicalId\":31717,\"journal\":{\"name\":\"Simetris Jurnal Teknik Mesin Elektro dan Ilmu Komputer\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Simetris Jurnal Teknik Mesin Elektro dan Ilmu Komputer\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47685/mestro.v5i02.365\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Simetris Jurnal Teknik Mesin Elektro dan Ilmu Komputer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47685/mestro.v5i02.365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

泵是一种流体机械,其用途非常广泛和重要,从工业到家庭都需要。选择泵的性能特性是非常重要的,必须调整到需要,其中包括:流量,扬程,功率和旋转。通过试验,获得了泵的性能特性。考虑到泵性能特性信息的重要性,通过这项研究活动,将努力测试使用3马力的离心泵。在这项研究中,从直接测试结果中获得的数据将被输入,在机器性能测试实验室进行测试。在此试验中,从压力表中逐渐得到几个阀门开度的泵压力数据,然后将数据输入已准备好的数据表中。利用研制的3马力离心泵试验设备作为发动机性能试验的实验室泵试验设备之一,进行了离心泵试验设备的性能试验。在测试离心泵时,有3个变量将用于进行测试,即第一个是使用转速计,用于测量轴的旋转,第二个是使用波顿压力计,用于测量流体压力,第三个是使用孔板,用于测量流体的速度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance Testing of Centrifugal Pump Type with 3 Hp Power
Pumps are fluid machines whose uses are very broad and important, ranging from industry to household needs. Selection of pump performance characteristics is very important and must be adjusted to the needs which include: discharge, head, power, and rotation. The performance characteristics of the pump are obtained through testing. In connection with the importance of information about pump performance characteristics, through this research activity efforts will be made to test centrifugal pumps using 3 hp of power. In this research, the data obtained from the direct test results will be entered, where the test is carried out at the Machine Performance Test Laboratory. In this test, the pump pressure data obtained from the gauge gradually with several valve openings, then the data is entered into the data table that has been prepared. The test was carried out to test the ability of the centrifugal pump test equipment using 3 HP power which was prepared as one of the laboratory pump test equipment for engine performance testing. In testing the centrifugal pump there are 3 variables that will be used to carry out the test, namely the first by using a tachometer which is useful for measuring shaft rotation, the second by using a Bordoun manometer which is useful for measuring fluid pressure, the third by using an orifice which functions to measure speed fluid.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信