发电机定子棒绝缘的pd活性随电压、频率和温度的变化

T. Aakre, E. Ildstad
{"title":"发电机定子棒绝缘的pd活性随电压、频率和温度的变化","authors":"T. Aakre, E. Ildstad","doi":"10.1109/ICD46958.2020.9341874","DOIUrl":null,"url":null,"abstract":"Condition assessment of generators is today performed at various voltage frequencies and test temperatures. The main purpose of this paper is to compare measured PD results from sections of generator bars with that of similar tests performed on laboratory made test objects with void enclosures of known geometry. The test objects were subjected to ac voltage in the frequency range from 0.1 to 300 Hz, increasing in steps up to a maximum of 10 kV. The measured values of partial discharge inception voltages (PDIV), apparent charge magnitude and number of PDs were compared to estimated values in the temperature range of 20° to $155^{\\circ}\\mathrm{C}$ using an impedance abcmodel, including both conduction and dielectric response. It was found that the capacitive abc-model sufficiently accurately describes the observed PDIV values at temperatures below $100^{\\circ}\\mathrm{C}$ and test frequencies below 50 Hz. At temperatures higher temperatures the measured PDIV values were found to decrease with increasing temperature, particularly so at the lowest test frequencies. This is in agreement with the assumption of increased conductivity and higher rate of polarization at increased temperatures. The high number of low magnitude PDs, strongly indicating that several discharges are needed for a complete discharge of a void surface.","PeriodicalId":6795,"journal":{"name":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","volume":"1 1","pages":"870-873"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PD-Activity in Generator Stator Bar insulation versus Voltage Frequency and Temperature\",\"authors\":\"T. Aakre, E. Ildstad\",\"doi\":\"10.1109/ICD46958.2020.9341874\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Condition assessment of generators is today performed at various voltage frequencies and test temperatures. The main purpose of this paper is to compare measured PD results from sections of generator bars with that of similar tests performed on laboratory made test objects with void enclosures of known geometry. The test objects were subjected to ac voltage in the frequency range from 0.1 to 300 Hz, increasing in steps up to a maximum of 10 kV. The measured values of partial discharge inception voltages (PDIV), apparent charge magnitude and number of PDs were compared to estimated values in the temperature range of 20° to $155^{\\\\circ}\\\\mathrm{C}$ using an impedance abcmodel, including both conduction and dielectric response. It was found that the capacitive abc-model sufficiently accurately describes the observed PDIV values at temperatures below $100^{\\\\circ}\\\\mathrm{C}$ and test frequencies below 50 Hz. At temperatures higher temperatures the measured PDIV values were found to decrease with increasing temperature, particularly so at the lowest test frequencies. This is in agreement with the assumption of increased conductivity and higher rate of polarization at increased temperatures. The high number of low magnitude PDs, strongly indicating that several discharges are needed for a complete discharge of a void surface.\",\"PeriodicalId\":6795,\"journal\":{\"name\":\"2020 IEEE 3rd International Conference on Dielectrics (ICD)\",\"volume\":\"1 1\",\"pages\":\"870-873\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 3rd International Conference on Dielectrics (ICD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICD46958.2020.9341874\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICD46958.2020.9341874","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

发电机的状态评估目前在各种电压频率和测试温度下进行。本文的主要目的是比较发电机棒部分的测量PD结果与在实验室制造的具有已知几何形状的空洞外壳的测试对象上进行的类似测试的结果。测试对象承受0.1至300 Hz频率范围内的交流电压,逐步增加,最高可达10 kV。在20°~ 155^{\circ}\ mathm {C}$的温度范围内,利用阻抗abcmodel(包括传导和介电响应)将局部放电起始电压(PDIV)、视电荷大小和局部放电数的测量值与估计值进行了比较。结果表明,电容式abc模型能够充分准确地描述温度低于$100^{\circ}\ mathm {C}$和测试频率低于50 Hz时观测到的PDIV值。在较高的温度下,PDIV值随着温度的升高而降低,特别是在最低的测试频率下。这与在温度升高时电导率增加和极化率提高的假设是一致的。大量的低量级脉冲放电,强烈表明需要多次放电才能使空洞表面完全放电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PD-Activity in Generator Stator Bar insulation versus Voltage Frequency and Temperature
Condition assessment of generators is today performed at various voltage frequencies and test temperatures. The main purpose of this paper is to compare measured PD results from sections of generator bars with that of similar tests performed on laboratory made test objects with void enclosures of known geometry. The test objects were subjected to ac voltage in the frequency range from 0.1 to 300 Hz, increasing in steps up to a maximum of 10 kV. The measured values of partial discharge inception voltages (PDIV), apparent charge magnitude and number of PDs were compared to estimated values in the temperature range of 20° to $155^{\circ}\mathrm{C}$ using an impedance abcmodel, including both conduction and dielectric response. It was found that the capacitive abc-model sufficiently accurately describes the observed PDIV values at temperatures below $100^{\circ}\mathrm{C}$ and test frequencies below 50 Hz. At temperatures higher temperatures the measured PDIV values were found to decrease with increasing temperature, particularly so at the lowest test frequencies. This is in agreement with the assumption of increased conductivity and higher rate of polarization at increased temperatures. The high number of low magnitude PDs, strongly indicating that several discharges are needed for a complete discharge of a void surface.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信