{"title":"基于改进PQ法的五级和七级NPC逆变器串联APF","authors":"Salim Chennai","doi":"10.46904/eea.23.71.1.1108003","DOIUrl":null,"url":null,"abstract":"This paper presents the performance analysis of Series Active Power Filter (Series APF) based on five and seven-level neutral point clamped (npc) using modified instantaneous reactive power control strategy to use for harmonic and all voltage disturbances compensation. The conventional configuration based on standard voltage source inverter (VSI) with hysteresis controller presents several drawbacks such us uneven switching frequency and limited power applications. Multi-level inverters such us Five and seven-level are currently being investigated and used in various industrial applications; their advantages include the capability to reduce the harmonic content and decrease the voltage or current ratings of the semiconductors with low switching losses, low electromagnetic interference, and low acoustic noise. Fuzzy controllers are successfully employed in various industrial applications and are found more robust than conventional controllers; they represent a good alternative to classic control systems. To benefit of all these advantages two configuration of Series APF are presented in this paper adopting the same control scheme based on Phase Disposition-Sinusoidal Pulse Width Modulation (PD-SPWM) and fuzzy logic control (FLC). The proposed two series APF are evaluated using MATLAB-Simulink software and SimPowerSystem Toolbox for harmonic compensation and in case of all voltage disturbances compensation. The simulation results show the performance and the efficiency of the proposed Series APF based on seven-lever (npc) inverter in the improvement of the power quality.","PeriodicalId":38292,"journal":{"name":"EEA - Electrotehnica, Electronica, Automatica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Series APF based on Five and Seven-Level NPC Inverters using modified PQ Method\",\"authors\":\"Salim Chennai\",\"doi\":\"10.46904/eea.23.71.1.1108003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the performance analysis of Series Active Power Filter (Series APF) based on five and seven-level neutral point clamped (npc) using modified instantaneous reactive power control strategy to use for harmonic and all voltage disturbances compensation. The conventional configuration based on standard voltage source inverter (VSI) with hysteresis controller presents several drawbacks such us uneven switching frequency and limited power applications. Multi-level inverters such us Five and seven-level are currently being investigated and used in various industrial applications; their advantages include the capability to reduce the harmonic content and decrease the voltage or current ratings of the semiconductors with low switching losses, low electromagnetic interference, and low acoustic noise. Fuzzy controllers are successfully employed in various industrial applications and are found more robust than conventional controllers; they represent a good alternative to classic control systems. To benefit of all these advantages two configuration of Series APF are presented in this paper adopting the same control scheme based on Phase Disposition-Sinusoidal Pulse Width Modulation (PD-SPWM) and fuzzy logic control (FLC). The proposed two series APF are evaluated using MATLAB-Simulink software and SimPowerSystem Toolbox for harmonic compensation and in case of all voltage disturbances compensation. The simulation results show the performance and the efficiency of the proposed Series APF based on seven-lever (npc) inverter in the improvement of the power quality.\",\"PeriodicalId\":38292,\"journal\":{\"name\":\"EEA - Electrotehnica, Electronica, Automatica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EEA - Electrotehnica, Electronica, Automatica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46904/eea.23.71.1.1108003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EEA - Electrotehnica, Electronica, Automatica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46904/eea.23.71.1.1108003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文分析了基于5级和7级中性点箝位(npc)的串联有源电力滤波器(Series APF)的性能,采用改进的瞬时无功控制策略对谐波和全电压干扰进行补偿。传统的基于迟滞控制器的标准电压源逆变器(VSI)存在开关频率不均匀和功率应用受限等缺点。5级和7级等多电平逆变器目前正在研究和应用于各种工业应用;它们的优点包括能够减少谐波含量,降低具有低开关损耗、低电磁干扰和低噪声的半导体的电压或电流额制值。模糊控制器已成功地应用于各种工业应用中,并且比传统控制器更具鲁棒性;它们代表了经典控制系统的一个很好的替代方案。为了充分利用这些优点,本文提出了两种采用相同控制方案的串联有源滤波器,即相位配置-正弦脉宽调制(PD-SPWM)和模糊逻辑控制(FLC)。利用MATLAB-Simulink软件和SimPowerSystem工具箱对所提出的两个系列有源滤波器进行了谐波补偿和所有电压干扰补偿。仿真结果表明,所提出的基于七电平逆变器的串联有源滤波器在改善电能质量方面具有良好的性能和效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Series APF based on Five and Seven-Level NPC Inverters using modified PQ Method
This paper presents the performance analysis of Series Active Power Filter (Series APF) based on five and seven-level neutral point clamped (npc) using modified instantaneous reactive power control strategy to use for harmonic and all voltage disturbances compensation. The conventional configuration based on standard voltage source inverter (VSI) with hysteresis controller presents several drawbacks such us uneven switching frequency and limited power applications. Multi-level inverters such us Five and seven-level are currently being investigated and used in various industrial applications; their advantages include the capability to reduce the harmonic content and decrease the voltage or current ratings of the semiconductors with low switching losses, low electromagnetic interference, and low acoustic noise. Fuzzy controllers are successfully employed in various industrial applications and are found more robust than conventional controllers; they represent a good alternative to classic control systems. To benefit of all these advantages two configuration of Series APF are presented in this paper adopting the same control scheme based on Phase Disposition-Sinusoidal Pulse Width Modulation (PD-SPWM) and fuzzy logic control (FLC). The proposed two series APF are evaluated using MATLAB-Simulink software and SimPowerSystem Toolbox for harmonic compensation and in case of all voltage disturbances compensation. The simulation results show the performance and the efficiency of the proposed Series APF based on seven-lever (npc) inverter in the improvement of the power quality.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
EEA - Electrotehnica, Electronica, Automatica
EEA - Electrotehnica, Electronica, Automatica Engineering-Electrical and Electronic Engineering
CiteScore
0.90
自引率
0.00%
发文量
26
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信