J. Piazze, M. Anceschi, A. Berretta, S. Vitali, L. Maranghi, F. Amici, E. Cosmi
{"title":"结合计算机心电图和羊水指数预测新生儿出生时酸血症:一种改良的生物物理剖面。","authors":"J. Piazze, M. Anceschi, A. Berretta, S. Vitali, L. Maranghi, F. Amici, E. Cosmi","doi":"10.1080/714052769","DOIUrl":null,"url":null,"abstract":"Objective: To study the combination of computerized cardiotocography (cCTG) and the amniotic fluid index (AFI) in the prediction of neonatal acidemia at birth. Methods: A total of 89 singleton third-trimester high-risk pregnancies delivered by Cesarean section, with an AFI evaluated within 24 h from birth, and an antepartum cCTG performed within 6 h from delivery, were studied. The score was the sum of values for AFI (oligo/anhydramnios = 1, normal = 0) and cCTG (Dawes-Redman criteria, not met = 1, met = 0). The endpoint was to predict an abnormal neonatal outcome as defined by an umbilical artery pH of h 7.2. Results: Fifteen neonates had an umbilical artery pH of < 7.2. The combination of cCTG + AFI score was able to predict pH values ( h 7.20) with an OR = 2.83 ( p < 0.02). The diagnostic accuracy of the combination of cCTG + AFI was as follows: sensitivity 80%, specificity 58%, positive predictive value 28%, negative predictive value 83%. Comment: We suggest that the cCTG + AFI score may be of...","PeriodicalId":79464,"journal":{"name":"The Journal of maternal-fetal medicine","volume":"1 1","pages":"323-327"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The combination of computerized cardiotocography and amniotic fluid index for the prediction of neonatal acidemia at birth: a modified biophysical profile.\",\"authors\":\"J. Piazze, M. Anceschi, A. Berretta, S. Vitali, L. Maranghi, F. Amici, E. Cosmi\",\"doi\":\"10.1080/714052769\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To study the combination of computerized cardiotocography (cCTG) and the amniotic fluid index (AFI) in the prediction of neonatal acidemia at birth. Methods: A total of 89 singleton third-trimester high-risk pregnancies delivered by Cesarean section, with an AFI evaluated within 24 h from birth, and an antepartum cCTG performed within 6 h from delivery, were studied. The score was the sum of values for AFI (oligo/anhydramnios = 1, normal = 0) and cCTG (Dawes-Redman criteria, not met = 1, met = 0). The endpoint was to predict an abnormal neonatal outcome as defined by an umbilical artery pH of h 7.2. Results: Fifteen neonates had an umbilical artery pH of < 7.2. The combination of cCTG + AFI score was able to predict pH values ( h 7.20) with an OR = 2.83 ( p < 0.02). The diagnostic accuracy of the combination of cCTG + AFI was as follows: sensitivity 80%, specificity 58%, positive predictive value 28%, negative predictive value 83%. Comment: We suggest that the cCTG + AFI score may be of...\",\"PeriodicalId\":79464,\"journal\":{\"name\":\"The Journal of maternal-fetal medicine\",\"volume\":\"1 1\",\"pages\":\"323-327\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of maternal-fetal medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/714052769\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of maternal-fetal medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/714052769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The combination of computerized cardiotocography and amniotic fluid index for the prediction of neonatal acidemia at birth: a modified biophysical profile.
Objective: To study the combination of computerized cardiotocography (cCTG) and the amniotic fluid index (AFI) in the prediction of neonatal acidemia at birth. Methods: A total of 89 singleton third-trimester high-risk pregnancies delivered by Cesarean section, with an AFI evaluated within 24 h from birth, and an antepartum cCTG performed within 6 h from delivery, were studied. The score was the sum of values for AFI (oligo/anhydramnios = 1, normal = 0) and cCTG (Dawes-Redman criteria, not met = 1, met = 0). The endpoint was to predict an abnormal neonatal outcome as defined by an umbilical artery pH of h 7.2. Results: Fifteen neonates had an umbilical artery pH of < 7.2. The combination of cCTG + AFI score was able to predict pH values ( h 7.20) with an OR = 2.83 ( p < 0.02). The diagnostic accuracy of the combination of cCTG + AFI was as follows: sensitivity 80%, specificity 58%, positive predictive value 28%, negative predictive value 83%. Comment: We suggest that the cCTG + AFI score may be of...