优化定量冠状动脉造影边缘检测:问题与建议

W. Wunderlich, T. Linderer, B. Backs, F. Fischer, J. Noering, R. Schroeder
{"title":"优化定量冠状动脉造影边缘检测:问题与建议","authors":"W. Wunderlich, T. Linderer, B. Backs, F. Fischer, J. Noering, R. Schroeder","doi":"10.1109/CIC.1993.378335","DOIUrl":null,"url":null,"abstract":"Optimum geometric edge detection in quantitative coronary arteriography (QCA) is determined by the accuracy of measurements of known phantom diameters. The authors optimized the edge detection for different calibration methods, diameter ranges, accuracy measures and performance strategies. They found, that the optimization process itself is ill-defined, depending on the calibration method used, the included range of small diameters and the accuracy measure. For detectability of diameter changes accuracy-optimized edge detection is inferior to precision-optimum approach. The optimization of both, accuracy and precision can only be achieved with a precision-optimum approach and diameter correction.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"1 1","pages":"583-586"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Optimizing edge detection in quantitative coronary arteriography: problems and proposals\",\"authors\":\"W. Wunderlich, T. Linderer, B. Backs, F. Fischer, J. Noering, R. Schroeder\",\"doi\":\"10.1109/CIC.1993.378335\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Optimum geometric edge detection in quantitative coronary arteriography (QCA) is determined by the accuracy of measurements of known phantom diameters. The authors optimized the edge detection for different calibration methods, diameter ranges, accuracy measures and performance strategies. They found, that the optimization process itself is ill-defined, depending on the calibration method used, the included range of small diameters and the accuracy measure. For detectability of diameter changes accuracy-optimized edge detection is inferior to precision-optimum approach. The optimization of both, accuracy and precision can only be achieved with a precision-optimum approach and diameter correction.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"1 1\",\"pages\":\"583-586\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378335\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378335","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

定量冠状动脉造影(QCA)中的最佳几何边缘检测是由已知幻像直径测量的准确性决定的。作者针对不同的标定方法、直径范围、精度度量和性能策略对边缘检测进行了优化。他们发现,优化过程本身是不明确的,这取决于所使用的校准方法,包括小直径的范围和精度测量。对于直径变化的可检测性,精度优化边缘检测不如精度优化边缘检测。精度和精度的优化只能通过精度优化方法和直径校正来实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimizing edge detection in quantitative coronary arteriography: problems and proposals
Optimum geometric edge detection in quantitative coronary arteriography (QCA) is determined by the accuracy of measurements of known phantom diameters. The authors optimized the edge detection for different calibration methods, diameter ranges, accuracy measures and performance strategies. They found, that the optimization process itself is ill-defined, depending on the calibration method used, the included range of small diameters and the accuracy measure. For detectability of diameter changes accuracy-optimized edge detection is inferior to precision-optimum approach. The optimization of both, accuracy and precision can only be achieved with a precision-optimum approach and diameter correction.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信