风电变流器基于输出功率的不固定开关频率调制方法

Jing Huang, Gang Zhang, Wei-jun Pan
{"title":"风电变流器基于输出功率的不固定开关频率调制方法","authors":"Jing Huang, Gang Zhang, Wei-jun Pan","doi":"10.12783/dtetr/acaai2020/34183","DOIUrl":null,"url":null,"abstract":"The wind turbine power system is being widely used and heavily connected to the utility grid, and the total harmonic distortion (THD) is one of the major evaluation indicators of electric power quality. The characteristics of the grid-connected wind converter harmonic with variable power loading are analyzed in this paper, and a software method of the variable switching frequency based on the output power of wind power converter is investigated to improve the grid-connecting harmonic considering the widely power loading. The method is verified on a three-level Neutral-Point-Clamped converter with Sinusoidal Pulse Width Modulation through simulations at last. And the results show that the THD is improved clearly and meanwhile the power loss and junction temperature are improved.","PeriodicalId":11264,"journal":{"name":"DEStech Transactions on Engineering and Technology Research","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Modulation Method with Unfixed Switching Frequency Based on Output Power for Wind Power Converter\",\"authors\":\"Jing Huang, Gang Zhang, Wei-jun Pan\",\"doi\":\"10.12783/dtetr/acaai2020/34183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The wind turbine power system is being widely used and heavily connected to the utility grid, and the total harmonic distortion (THD) is one of the major evaluation indicators of electric power quality. The characteristics of the grid-connected wind converter harmonic with variable power loading are analyzed in this paper, and a software method of the variable switching frequency based on the output power of wind power converter is investigated to improve the grid-connecting harmonic considering the widely power loading. The method is verified on a three-level Neutral-Point-Clamped converter with Sinusoidal Pulse Width Modulation through simulations at last. And the results show that the THD is improved clearly and meanwhile the power loss and junction temperature are improved.\",\"PeriodicalId\":11264,\"journal\":{\"name\":\"DEStech Transactions on Engineering and Technology Research\",\"volume\":\"22 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DEStech Transactions on Engineering and Technology Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12783/dtetr/acaai2020/34183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DEStech Transactions on Engineering and Technology Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12783/dtetr/acaai2020/34183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

风力发电系统被广泛应用并大量接入电网,总谐波失真(THD)是电力质量的主要评价指标之一。分析了变功率负荷下并网风电变流器谐波特性,研究了一种基于风电变流器输出功率的变开关频率的软件方法,在考虑大功率负荷的情况下改善并网谐波。最后在三电平中点箝位正弦脉宽调制变换器上进行了仿真验证。结果表明,该方法明显改善了THD,同时提高了功耗和结温。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Modulation Method with Unfixed Switching Frequency Based on Output Power for Wind Power Converter
The wind turbine power system is being widely used and heavily connected to the utility grid, and the total harmonic distortion (THD) is one of the major evaluation indicators of electric power quality. The characteristics of the grid-connected wind converter harmonic with variable power loading are analyzed in this paper, and a software method of the variable switching frequency based on the output power of wind power converter is investigated to improve the grid-connecting harmonic considering the widely power loading. The method is verified on a three-level Neutral-Point-Clamped converter with Sinusoidal Pulse Width Modulation through simulations at last. And the results show that the THD is improved clearly and meanwhile the power loss and junction temperature are improved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信