A. Bharati, S. Mandal, A. Srivastava, M. Rastogi, R. Khurana, R. Hadi, A. Gandhi, Lalatendu Mishra, S. Mishra
{"title":"通过使用NTCP和TCP模型对膀胱肿瘤进行剂量对水和剂量对介质的临床意义评估","authors":"A. Bharati, S. Mandal, A. Srivastava, M. Rastogi, R. Khurana, R. Hadi, A. Gandhi, Lalatendu Mishra, S. Mishra","doi":"10.2478/pjmpe-2021-0003","DOIUrl":null,"url":null,"abstract":"Abstract Purpose: To analyze the dosimetric and radiobiological differences between dose to water versus dose to medium for patients with carcinoma of the urinary bladder. Materials and Methods: 15 patients with cancer of urinary bladder were selected for the study. VMAT plans were generated for each patient. The dose distributions were calculated in the modes dose to water and to medium with the Monaco treatment planning system. A dosimetric comparative analysis has been made between the two modes of planning in this study. Subsequently, NTCP and TCP were determined for OARs and targets respectively. Results: The mean dose to 2 cc of the rectum, small bowel, left and right femoral heads respectively was higher by 0.8, 1.2, 2.7, and 2.2% for the dose to water calculation. Similarly, the mean dose to D2, D50, and D98 for PTV was higher by 0.4, 0.3, and 0.3% for dose to water calculation. Such small dose differences had little effect on the values of TCP and NTCP. Conclusion: For patients with the urinary bladder there were very small differences between results between calculations carried out in dose to medium and dose to water modes.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"50 1","pages":"19 - 24"},"PeriodicalIF":0.7000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evaluation of clinical implications in the use of dose to water versus dose to medium by using NTCP and TCP models for urinary bladder tumours\",\"authors\":\"A. Bharati, S. Mandal, A. Srivastava, M. Rastogi, R. Khurana, R. Hadi, A. Gandhi, Lalatendu Mishra, S. Mishra\",\"doi\":\"10.2478/pjmpe-2021-0003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Purpose: To analyze the dosimetric and radiobiological differences between dose to water versus dose to medium for patients with carcinoma of the urinary bladder. Materials and Methods: 15 patients with cancer of urinary bladder were selected for the study. VMAT plans were generated for each patient. The dose distributions were calculated in the modes dose to water and to medium with the Monaco treatment planning system. A dosimetric comparative analysis has been made between the two modes of planning in this study. Subsequently, NTCP and TCP were determined for OARs and targets respectively. Results: The mean dose to 2 cc of the rectum, small bowel, left and right femoral heads respectively was higher by 0.8, 1.2, 2.7, and 2.2% for the dose to water calculation. Similarly, the mean dose to D2, D50, and D98 for PTV was higher by 0.4, 0.3, and 0.3% for dose to water calculation. Such small dose differences had little effect on the values of TCP and NTCP. Conclusion: For patients with the urinary bladder there were very small differences between results between calculations carried out in dose to medium and dose to water modes.\",\"PeriodicalId\":53955,\"journal\":{\"name\":\"Polish Journal of Medical Physics and Engineering\",\"volume\":\"50 1\",\"pages\":\"19 - 24\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Medical Physics and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/pjmpe-2021-0003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Medical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/pjmpe-2021-0003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Evaluation of clinical implications in the use of dose to water versus dose to medium by using NTCP and TCP models for urinary bladder tumours
Abstract Purpose: To analyze the dosimetric and radiobiological differences between dose to water versus dose to medium for patients with carcinoma of the urinary bladder. Materials and Methods: 15 patients with cancer of urinary bladder were selected for the study. VMAT plans were generated for each patient. The dose distributions were calculated in the modes dose to water and to medium with the Monaco treatment planning system. A dosimetric comparative analysis has been made between the two modes of planning in this study. Subsequently, NTCP and TCP were determined for OARs and targets respectively. Results: The mean dose to 2 cc of the rectum, small bowel, left and right femoral heads respectively was higher by 0.8, 1.2, 2.7, and 2.2% for the dose to water calculation. Similarly, the mean dose to D2, D50, and D98 for PTV was higher by 0.4, 0.3, and 0.3% for dose to water calculation. Such small dose differences had little effect on the values of TCP and NTCP. Conclusion: For patients with the urinary bladder there were very small differences between results between calculations carried out in dose to medium and dose to water modes.
期刊介绍:
Polish Journal of Medical Physics and Engineering (PJMPE) (Online ISSN: 1898-0309; Print ISSN: 1425-4689) is an official publication of the Polish Society of Medical Physics. It is a peer-reviewed, open access scientific journal with no publication fees. The issues are published quarterly online. The Journal publishes original contribution in medical physics and biomedical engineering.