通过使用NTCP和TCP模型对膀胱肿瘤进行剂量对水和剂量对介质的临床意义评估

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
A. Bharati, S. Mandal, A. Srivastava, M. Rastogi, R. Khurana, R. Hadi, A. Gandhi, Lalatendu Mishra, S. Mishra
{"title":"通过使用NTCP和TCP模型对膀胱肿瘤进行剂量对水和剂量对介质的临床意义评估","authors":"A. Bharati, S. Mandal, A. Srivastava, M. Rastogi, R. Khurana, R. Hadi, A. Gandhi, Lalatendu Mishra, S. Mishra","doi":"10.2478/pjmpe-2021-0003","DOIUrl":null,"url":null,"abstract":"Abstract Purpose: To analyze the dosimetric and radiobiological differences between dose to water versus dose to medium for patients with carcinoma of the urinary bladder. Materials and Methods: 15 patients with cancer of urinary bladder were selected for the study. VMAT plans were generated for each patient. The dose distributions were calculated in the modes dose to water and to medium with the Monaco treatment planning system. A dosimetric comparative analysis has been made between the two modes of planning in this study. Subsequently, NTCP and TCP were determined for OARs and targets respectively. Results: The mean dose to 2 cc of the rectum, small bowel, left and right femoral heads respectively was higher by 0.8, 1.2, 2.7, and 2.2% for the dose to water calculation. Similarly, the mean dose to D2, D50, and D98 for PTV was higher by 0.4, 0.3, and 0.3% for dose to water calculation. Such small dose differences had little effect on the values of TCP and NTCP. Conclusion: For patients with the urinary bladder there were very small differences between results between calculations carried out in dose to medium and dose to water modes.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"50 1","pages":"19 - 24"},"PeriodicalIF":0.7000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evaluation of clinical implications in the use of dose to water versus dose to medium by using NTCP and TCP models for urinary bladder tumours\",\"authors\":\"A. Bharati, S. Mandal, A. Srivastava, M. Rastogi, R. Khurana, R. Hadi, A. Gandhi, Lalatendu Mishra, S. Mishra\",\"doi\":\"10.2478/pjmpe-2021-0003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Purpose: To analyze the dosimetric and radiobiological differences between dose to water versus dose to medium for patients with carcinoma of the urinary bladder. Materials and Methods: 15 patients with cancer of urinary bladder were selected for the study. VMAT plans were generated for each patient. The dose distributions were calculated in the modes dose to water and to medium with the Monaco treatment planning system. A dosimetric comparative analysis has been made between the two modes of planning in this study. Subsequently, NTCP and TCP were determined for OARs and targets respectively. Results: The mean dose to 2 cc of the rectum, small bowel, left and right femoral heads respectively was higher by 0.8, 1.2, 2.7, and 2.2% for the dose to water calculation. Similarly, the mean dose to D2, D50, and D98 for PTV was higher by 0.4, 0.3, and 0.3% for dose to water calculation. Such small dose differences had little effect on the values of TCP and NTCP. Conclusion: For patients with the urinary bladder there were very small differences between results between calculations carried out in dose to medium and dose to water modes.\",\"PeriodicalId\":53955,\"journal\":{\"name\":\"Polish Journal of Medical Physics and Engineering\",\"volume\":\"50 1\",\"pages\":\"19 - 24\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Medical Physics and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/pjmpe-2021-0003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Medical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/pjmpe-2021-0003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 1

摘要

摘要目的:分析膀胱癌患者水剂量与介质剂量在剂量学和放射生物学上的差异。材料与方法:选取15例膀胱癌患者作为研究对象。为每位患者生成VMAT计划。用摩纳哥处理计划系统计算了对水和对介质的剂量分布。本研究对两种规划模式进行了剂量学比较分析。随后,分别确定了桨和目标的NTCP和TCP。结果:直肠、小肠、左股骨头、右股骨头2 cc的平均入水剂量分别高出0.8、1.2、2.7、2.2%。同样,PTV对D2、D50和D98的平均剂量在对水的剂量计算中分别高出0.4、0.3和0.3%。如此小的剂量差异对TCP和NTCP值影响不大。结论:对于膀胱患者,中剂量模式与水剂量模式的计算结果差异极小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of clinical implications in the use of dose to water versus dose to medium by using NTCP and TCP models for urinary bladder tumours
Abstract Purpose: To analyze the dosimetric and radiobiological differences between dose to water versus dose to medium for patients with carcinoma of the urinary bladder. Materials and Methods: 15 patients with cancer of urinary bladder were selected for the study. VMAT plans were generated for each patient. The dose distributions were calculated in the modes dose to water and to medium with the Monaco treatment planning system. A dosimetric comparative analysis has been made between the two modes of planning in this study. Subsequently, NTCP and TCP were determined for OARs and targets respectively. Results: The mean dose to 2 cc of the rectum, small bowel, left and right femoral heads respectively was higher by 0.8, 1.2, 2.7, and 2.2% for the dose to water calculation. Similarly, the mean dose to D2, D50, and D98 for PTV was higher by 0.4, 0.3, and 0.3% for dose to water calculation. Such small dose differences had little effect on the values of TCP and NTCP. Conclusion: For patients with the urinary bladder there were very small differences between results between calculations carried out in dose to medium and dose to water modes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polish Journal of Medical Physics and Engineering
Polish Journal of Medical Physics and Engineering RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.30
自引率
0.00%
发文量
19
期刊介绍: Polish Journal of Medical Physics and Engineering (PJMPE) (Online ISSN: 1898-0309; Print ISSN: 1425-4689) is an official publication of the Polish Society of Medical Physics. It is a peer-reviewed, open access scientific journal with no publication fees. The issues are published quarterly online. The Journal publishes original contribution in medical physics and biomedical engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信