252cf -等离子解吸质谱多站时间数字化仪

B.T. Turko , R.D. Macfarlane , C.J. McNeal
{"title":"252cf -等离子解吸质谱多站时间数字化仪","authors":"B.T. Turko ,&nbsp;R.D. Macfarlane ,&nbsp;C.J. McNeal","doi":"10.1016/0020-7381(83)85130-4","DOIUrl":null,"url":null,"abstract":"<div><p>A multistop time digitizer is described which was designed specifically for <sup>252</sup>Cf-plasma desorption time-of-flight mass spectrometry. The digitizer is a high resolution time intervalometer capable of measuring the times of a number of stop events following a common start. A resolution of 78.125 ps is achieved. The time range can be varied from 5 ms to 320 ms in 16 steps. Stop event processing time takes less than one microsecond, enabling high resolution measurements of closely spaced bursts of events.</p><p>The digitizer consists of the following three modules. A clock module provides the accurate time reference including a precision time calibrator. An analog module contains a special tandem stretcher by which the high resolution and low differential nonlinearity are achieved. A digital module comprises the counting, logic and interface circuits. Up to four complete digitizers can be housed in and powered by a standard CAMAC crate.</p></div>","PeriodicalId":13998,"journal":{"name":"International Journal of Mass Spectrometry and Ion Physics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1983-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0020-7381(83)85130-4","citationCount":"16","resultStr":"{\"title\":\"252Cf-plasma desorption mass spectrometry multistop time digitizer\",\"authors\":\"B.T. Turko ,&nbsp;R.D. Macfarlane ,&nbsp;C.J. McNeal\",\"doi\":\"10.1016/0020-7381(83)85130-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A multistop time digitizer is described which was designed specifically for <sup>252</sup>Cf-plasma desorption time-of-flight mass spectrometry. The digitizer is a high resolution time intervalometer capable of measuring the times of a number of stop events following a common start. A resolution of 78.125 ps is achieved. The time range can be varied from 5 ms to 320 ms in 16 steps. Stop event processing time takes less than one microsecond, enabling high resolution measurements of closely spaced bursts of events.</p><p>The digitizer consists of the following three modules. A clock module provides the accurate time reference including a precision time calibrator. An analog module contains a special tandem stretcher by which the high resolution and low differential nonlinearity are achieved. A digital module comprises the counting, logic and interface circuits. Up to four complete digitizers can be housed in and powered by a standard CAMAC crate.</p></div>\",\"PeriodicalId\":13998,\"journal\":{\"name\":\"International Journal of Mass Spectrometry and Ion Physics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0020-7381(83)85130-4\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Mass Spectrometry and Ion Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0020738183851304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Mass Spectrometry and Ion Physics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0020738183851304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

描述了一种专门为252cf等离子体解吸飞行时间质谱设计的多站时间数字化仪。数字化仪是一种高分辨率时间间隔计,能够测量一次共同启动后若干停止事件的时间。分辨率达到78.125 ps。时间范围可以从5毫秒到320毫秒,分为16步。停止事件处理时间少于一微秒,因此可以对间隔很近的事件爆发进行高分辨率测量。数字化仪由以下三个模块组成。时钟模块提供精确的时间参考,包括精确的时间校准器。模拟模块包含一个特殊的串联拉伸器,通过它可以实现高分辨率和低微分非线性。数字模块包括计数电路、逻辑电路和接口电路。多达四个完整的数字转换器可以安置在一个标准的CAMAC板条箱中并由其供电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
252Cf-plasma desorption mass spectrometry multistop time digitizer

A multistop time digitizer is described which was designed specifically for 252Cf-plasma desorption time-of-flight mass spectrometry. The digitizer is a high resolution time intervalometer capable of measuring the times of a number of stop events following a common start. A resolution of 78.125 ps is achieved. The time range can be varied from 5 ms to 320 ms in 16 steps. Stop event processing time takes less than one microsecond, enabling high resolution measurements of closely spaced bursts of events.

The digitizer consists of the following three modules. A clock module provides the accurate time reference including a precision time calibrator. An analog module contains a special tandem stretcher by which the high resolution and low differential nonlinearity are achieved. A digital module comprises the counting, logic and interface circuits. Up to four complete digitizers can be housed in and powered by a standard CAMAC crate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信