温度和湿度对特高压直流输电线路无线电干扰的影响

Wei Wang, Bing An, Chengrong Li, B. Luo, Xiaolin Li, Yixu Wang, Fei Fan, Boo-gen Yang
{"title":"温度和湿度对特高压直流输电线路无线电干扰的影响","authors":"Wei Wang, Bing An, Chengrong Li, B. Luo, Xiaolin Li, Yixu Wang, Fei Fan, Boo-gen Yang","doi":"10.1109/CEIDP.2008.4772912","DOIUrl":null,"url":null,"abstract":"To research the effect of temperature and humidity on radio interference generated from UHV DC transmission lines, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, a radio interference performance measuring system by using loop method has been set up too. The radio interference generated from a copper line have been measured in a mini corona cage not only at different humidity from 30% to 99% at 20 but also at different temperature from 0 to 30. The relationship between radio interference level and temperature and humidity have been achieved.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"1 1","pages":"290-292"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The Effect of Temperature and Humidity on Radio Interference Generated from UHV DC Transmission Lines\",\"authors\":\"Wei Wang, Bing An, Chengrong Li, B. Luo, Xiaolin Li, Yixu Wang, Fei Fan, Boo-gen Yang\",\"doi\":\"10.1109/CEIDP.2008.4772912\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To research the effect of temperature and humidity on radio interference generated from UHV DC transmission lines, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, a radio interference performance measuring system by using loop method has been set up too. The radio interference generated from a copper line have been measured in a mini corona cage not only at different humidity from 30% to 99% at 20 but also at different temperature from 0 to 30. The relationship between radio interference level and temperature and humidity have been achieved.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"1 1\",\"pages\":\"290-292\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772912\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772912","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

为了研究温湿度对特高压直流输电线路产生的无线电干扰的影响,搭建了微型电晕笼,放置在可控制温湿度的人工环境室内。同时,还建立了一套基于环路法的无线电干扰性能测量系统。在微型电晕笼中,测量了不同湿度(30% ~ 99%,20℃)和不同温度(0 ~ 30℃)下铜线产生的无线电干扰。得到了无线电干扰水平与温度、湿度的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Temperature and Humidity on Radio Interference Generated from UHV DC Transmission Lines
To research the effect of temperature and humidity on radio interference generated from UHV DC transmission lines, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, a radio interference performance measuring system by using loop method has been set up too. The radio interference generated from a copper line have been measured in a mini corona cage not only at different humidity from 30% to 99% at 20 but also at different temperature from 0 to 30. The relationship between radio interference level and temperature and humidity have been achieved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信