考虑故障定位的配电系统电能质量监测器优化配置

P. E. T. Martins, M. Oleskovicz, A. Pessoa, Iago de Moura Faria
{"title":"考虑故障定位的配电系统电能质量监测器优化配置","authors":"P. E. T. Martins, M. Oleskovicz, A. Pessoa, Iago de Moura Faria","doi":"10.1109/ICHQP.2018.8378928","DOIUrl":null,"url":null,"abstract":"Short-duration voltage variations are disturbances of great concern, in the context of power quality. The permanent monitoring of these events is important because they are unpredictable and cause high economic losses to consumers. The strategic placement of power quality monitors has been studied, aiming, mostly, to reduce the installation cost of this monitoring system. However, it is more important not just monitoring these disturbances, but also identify their sources. This paper proposes a multi-objective approach, aiming, besides to reduce the cost also provide a meter allocation in favor of the location of the disturbance source. The optimization model proposed is solved by means of the Algorithm for Bicriteria Discrete Optimization and applied in IEEE 13 bus distribution test system. Several options of monitoring systems were obtained, respecting various constraints that influence decision making.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"3 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Optimized allocation of power quality monitors in distribution systems considering fault location\",\"authors\":\"P. E. T. Martins, M. Oleskovicz, A. Pessoa, Iago de Moura Faria\",\"doi\":\"10.1109/ICHQP.2018.8378928\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Short-duration voltage variations are disturbances of great concern, in the context of power quality. The permanent monitoring of these events is important because they are unpredictable and cause high economic losses to consumers. The strategic placement of power quality monitors has been studied, aiming, mostly, to reduce the installation cost of this monitoring system. However, it is more important not just monitoring these disturbances, but also identify their sources. This paper proposes a multi-objective approach, aiming, besides to reduce the cost also provide a meter allocation in favor of the location of the disturbance source. The optimization model proposed is solved by means of the Algorithm for Bicriteria Discrete Optimization and applied in IEEE 13 bus distribution test system. Several options of monitoring systems were obtained, respecting various constraints that influence decision making.\",\"PeriodicalId\":6506,\"journal\":{\"name\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"volume\":\"3 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2018.8378928\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378928","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在电能质量的背景下,短时电压变化是非常值得关注的干扰。对这些事件的长期监测很重要,因为它们是不可预测的,并给消费者造成巨大的经济损失。对电能质量监测器的配置策略进行了研究,主要目的是为了降低电能质量监控系统的安装成本。然而,更重要的是不仅要监测这些干扰,还要确定它们的来源。本文提出了一种多目标方法,目的是在降低成本的同时,提供有利于干扰源定位的仪表分配。采用双准则离散优化算法对所提出的优化模型进行求解,并将其应用于ieee13总线配电测试系统中。考虑到影响决策的各种制约因素,获得了几种监测系统的备选方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimized allocation of power quality monitors in distribution systems considering fault location
Short-duration voltage variations are disturbances of great concern, in the context of power quality. The permanent monitoring of these events is important because they are unpredictable and cause high economic losses to consumers. The strategic placement of power quality monitors has been studied, aiming, mostly, to reduce the installation cost of this monitoring system. However, it is more important not just monitoring these disturbances, but also identify their sources. This paper proposes a multi-objective approach, aiming, besides to reduce the cost also provide a meter allocation in favor of the location of the disturbance source. The optimization model proposed is solved by means of the Algorithm for Bicriteria Discrete Optimization and applied in IEEE 13 bus distribution test system. Several options of monitoring systems were obtained, respecting various constraints that influence decision making.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信