{"title":"气固混合绝缘系统电位分布揭示的势垒表面残余电荷","authors":"Yilong Wang, Qiongqiong Li, Shengwen Shu, Yuesheng Zheng","doi":"10.1109/ICHVE49031.2020.9279551","DOIUrl":null,"url":null,"abstract":"The characteristics of residual charges on the inserted barrier surfaces in different air-insulated insulation systems after alternating breakdowns are investigated. High voltage withstand tests and surface potential measurements were carried out. The results show that the potential polarity on the barrier surface is related to the voltage polarity at the moment of breakdown. The barrier surface potential where the discharge passes through is lower. Compared with the barrier position, the electrode radius has a more significant effect on the surface potential distribution after breakdown. As the electrode radius increases, the positive surface potential is higher and the area with the potential higher than 3 kV is larger. The surface potential decays slowly when the barrier is suspended. At last, the effect of residual charges revealed by the surface potential is discussed.","PeriodicalId":6763,"journal":{"name":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","volume":"18 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Residual Charges on Barrier Surface Revealed by Potential Distribution in a Hybrid Gas-Solid Insulation System\",\"authors\":\"Yilong Wang, Qiongqiong Li, Shengwen Shu, Yuesheng Zheng\",\"doi\":\"10.1109/ICHVE49031.2020.9279551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The characteristics of residual charges on the inserted barrier surfaces in different air-insulated insulation systems after alternating breakdowns are investigated. High voltage withstand tests and surface potential measurements were carried out. The results show that the potential polarity on the barrier surface is related to the voltage polarity at the moment of breakdown. The barrier surface potential where the discharge passes through is lower. Compared with the barrier position, the electrode radius has a more significant effect on the surface potential distribution after breakdown. As the electrode radius increases, the positive surface potential is higher and the area with the potential higher than 3 kV is larger. The surface potential decays slowly when the barrier is suspended. At last, the effect of residual charges revealed by the surface potential is discussed.\",\"PeriodicalId\":6763,\"journal\":{\"name\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"volume\":\"18 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE49031.2020.9279551\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE49031.2020.9279551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了不同空气绝缘绝缘系统交变击穿后插入障面残余电荷的特性。进行了高压耐压试验和表面电位测量。结果表明,势垒表面的电位极性与击穿时刻的电压极性有关。放电通过的屏障表面电位较低。与势垒位置相比,电极半径对击穿后表面电位分布的影响更为显著。电极半径越大,表面正电位越高,电位大于3kv的面积越大。当势垒悬浮时,表面电位衰减缓慢。最后讨论了表面电位显示的残余电荷的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Residual Charges on Barrier Surface Revealed by Potential Distribution in a Hybrid Gas-Solid Insulation System
The characteristics of residual charges on the inserted barrier surfaces in different air-insulated insulation systems after alternating breakdowns are investigated. High voltage withstand tests and surface potential measurements were carried out. The results show that the potential polarity on the barrier surface is related to the voltage polarity at the moment of breakdown. The barrier surface potential where the discharge passes through is lower. Compared with the barrier position, the electrode radius has a more significant effect on the surface potential distribution after breakdown. As the electrode radius increases, the positive surface potential is higher and the area with the potential higher than 3 kV is larger. The surface potential decays slowly when the barrier is suspended. At last, the effect of residual charges revealed by the surface potential is discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信