{"title":"利用正交逐拍记录自适应增强心室晚电位","authors":"Weiqun Yang, L. Horan, N. Flowers","doi":"10.1109/IEMBS.1992.5761102","DOIUrl":null,"url":null,"abstract":"A method for beat-by-beat recording of late potentials using adaptive filters is presented. An orthogonal lead set viewed as individual XYZ leads is employed for better detection of late potentials. The use of bidirectional and finite impulse response filters prevent filter ringing at the terminal QRS. Beat-by-beat late potentials detected from patients with ventricular tachycardia indicate the potential of this method, yet optimal filter parameters and quantitative criteria for detecting late potential are to be further investigated.","PeriodicalId":6457,"journal":{"name":"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"7 1","pages":"547-548"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Adaptive enhancement of ventricular late potentials using orthogonal beat-by-beat recordings\",\"authors\":\"Weiqun Yang, L. Horan, N. Flowers\",\"doi\":\"10.1109/IEMBS.1992.5761102\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method for beat-by-beat recording of late potentials using adaptive filters is presented. An orthogonal lead set viewed as individual XYZ leads is employed for better detection of late potentials. The use of bidirectional and finite impulse response filters prevent filter ringing at the terminal QRS. Beat-by-beat late potentials detected from patients with ventricular tachycardia indicate the potential of this method, yet optimal filter parameters and quantitative criteria for detecting late potential are to be further investigated.\",\"PeriodicalId\":6457,\"journal\":{\"name\":\"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"7 1\",\"pages\":\"547-548\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1992.5761102\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1992.5761102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Adaptive enhancement of ventricular late potentials using orthogonal beat-by-beat recordings
A method for beat-by-beat recording of late potentials using adaptive filters is presented. An orthogonal lead set viewed as individual XYZ leads is employed for better detection of late potentials. The use of bidirectional and finite impulse response filters prevent filter ringing at the terminal QRS. Beat-by-beat late potentials detected from patients with ventricular tachycardia indicate the potential of this method, yet optimal filter parameters and quantitative criteria for detecting late potential are to be further investigated.