扫描和透射电子显微镜的基础和应用

H. Zea
{"title":"扫描和透射电子显微镜的基础和应用","authors":"H. Zea","doi":"10.21767/0972-768X.1000292","DOIUrl":null,"url":null,"abstract":"Electron microscopes are equipment that use an accelerated electron beams as probes to generated images with magnifications and resolution not possible to obtain with optical microscopes (due to fact that electron wavelength can be 100,000 times shorter than visible light photons). Electron microscopes operating in the conventional high vacuum mode require conductive imaging specimens; therefore, non-conductive materials need the deposition of a conductive layer (Au-Pd alloys, carbon and osmium, among others). Low voltage mode of modern microscopes makes possible to observe non-conductive uncoated specimens. Transmission electron microscopes require thin samples (below 100 nm), placed onto appropriate sample holders. Electron microscopes are state of the art equipment that requires high operation and maintenance standards, therefore having a clear understanding of the operation fundamentals, equipment capabilities, suitable sample preparations and appropriate results interpretation is of critical importance to use the technique in the most suitable fashion.","PeriodicalId":13865,"journal":{"name":"international journal of chemical sciences","volume":"67 1","pages":"1-12"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fundamentals and Applications of Scanning and Transmission Electron Microscopes\",\"authors\":\"H. Zea\",\"doi\":\"10.21767/0972-768X.1000292\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electron microscopes are equipment that use an accelerated electron beams as probes to generated images with magnifications and resolution not possible to obtain with optical microscopes (due to fact that electron wavelength can be 100,000 times shorter than visible light photons). Electron microscopes operating in the conventional high vacuum mode require conductive imaging specimens; therefore, non-conductive materials need the deposition of a conductive layer (Au-Pd alloys, carbon and osmium, among others). Low voltage mode of modern microscopes makes possible to observe non-conductive uncoated specimens. Transmission electron microscopes require thin samples (below 100 nm), placed onto appropriate sample holders. Electron microscopes are state of the art equipment that requires high operation and maintenance standards, therefore having a clear understanding of the operation fundamentals, equipment capabilities, suitable sample preparations and appropriate results interpretation is of critical importance to use the technique in the most suitable fashion.\",\"PeriodicalId\":13865,\"journal\":{\"name\":\"international journal of chemical sciences\",\"volume\":\"67 1\",\"pages\":\"1-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"international journal of chemical sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21767/0972-768X.1000292\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"international journal of chemical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21767/0972-768X.1000292","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电子显微镜是一种使用加速电子束作为探针的设备,其产生的图像具有光学显微镜无法获得的放大倍率和分辨率(由于电子波长比可见光光子短10万倍)。在传统的高真空模式下操作的电子显微镜需要导电成像标本;因此,非导电材料需要沉积导电层(Au-Pd合金、碳和锇等)。现代显微镜的低电压模式使得观察不导电的未涂覆标本成为可能。透射电子显微镜需要薄样品(小于100纳米),放置在适当的样品支架上。电子显微镜是最先进的设备,需要很高的操作和维护标准,因此对操作基础,设备能力,合适的样品制备和适当的结果解释有清晰的了解对于以最合适的方式使用该技术至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fundamentals and Applications of Scanning and Transmission Electron Microscopes
Electron microscopes are equipment that use an accelerated electron beams as probes to generated images with magnifications and resolution not possible to obtain with optical microscopes (due to fact that electron wavelength can be 100,000 times shorter than visible light photons). Electron microscopes operating in the conventional high vacuum mode require conductive imaging specimens; therefore, non-conductive materials need the deposition of a conductive layer (Au-Pd alloys, carbon and osmium, among others). Low voltage mode of modern microscopes makes possible to observe non-conductive uncoated specimens. Transmission electron microscopes require thin samples (below 100 nm), placed onto appropriate sample holders. Electron microscopes are state of the art equipment that requires high operation and maintenance standards, therefore having a clear understanding of the operation fundamentals, equipment capabilities, suitable sample preparations and appropriate results interpretation is of critical importance to use the technique in the most suitable fashion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信