生物医学用新型紧凑型印刷折叠偶极子天线的设计

Sofia Bakogianni, S. Koulouridis
{"title":"生物医学用新型紧凑型印刷折叠偶极子天线的设计","authors":"Sofia Bakogianni, S. Koulouridis","doi":"10.1109/EUCAP.2014.6902503","DOIUrl":null,"url":null,"abstract":"In this study, a human tissue-implantable compact folded dipole antenna of 19.6 * 2 * 0.254 mm3 operating in the Medical Implant Communication Service (MICS) frequency band (402-405 MHz) is presented. The antenna design and analysis is carried out inside a homogeneous flat phantom with electrical properties equivalent to those of 2/3 human muscle tissue. The dipole antenna, printed on a high-dielectric substrate layer, exhibits a frequency resonance at 402 MHz with a wide 10-dB impedance bandwidth of 105 MHz. The proposed antenna radiates an omnidirectional far-field radiation pattern with a maximum realized gain of -31.2 dB. In addition, the Specific Absorption Rate (SAR) assessment indicates the maximum input power deliverable to the antenna in order to meet the required safety regulations.","PeriodicalId":22362,"journal":{"name":"The 8th European Conference on Antennas and Propagation (EuCAP 2014)","volume":"18 1","pages":"3178-3182"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Design of a novel compact printed folded dipole antenna for biomedical applications\",\"authors\":\"Sofia Bakogianni, S. Koulouridis\",\"doi\":\"10.1109/EUCAP.2014.6902503\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, a human tissue-implantable compact folded dipole antenna of 19.6 * 2 * 0.254 mm3 operating in the Medical Implant Communication Service (MICS) frequency band (402-405 MHz) is presented. The antenna design and analysis is carried out inside a homogeneous flat phantom with electrical properties equivalent to those of 2/3 human muscle tissue. The dipole antenna, printed on a high-dielectric substrate layer, exhibits a frequency resonance at 402 MHz with a wide 10-dB impedance bandwidth of 105 MHz. The proposed antenna radiates an omnidirectional far-field radiation pattern with a maximum realized gain of -31.2 dB. In addition, the Specific Absorption Rate (SAR) assessment indicates the maximum input power deliverable to the antenna in order to meet the required safety regulations.\",\"PeriodicalId\":22362,\"journal\":{\"name\":\"The 8th European Conference on Antennas and Propagation (EuCAP 2014)\",\"volume\":\"18 1\",\"pages\":\"3178-3182\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 8th European Conference on Antennas and Propagation (EuCAP 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUCAP.2014.6902503\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 8th European Conference on Antennas and Propagation (EuCAP 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUCAP.2014.6902503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

在这项研究中,提出了一种19.6 * 2 * 0.254 mm3的人体组织植入紧凑型折叠偶极子天线,工作在医疗植入通信服务(MICS)频段(402-405 MHz)。天线的设计和分析是在一个具有相当于2/3人体肌肉组织电性能的均匀扁平体中进行的。该偶极子天线印刷在高介电基片层上,显示出402 MHz的频率共振,10db宽阻抗带宽为105 MHz。该天线发射全向远场辐射方向图,最大实现增益为-31.2 dB。此外,特定吸收率(Specific Absorption Rate, SAR)评估是指天线可提供的最大输入功率,以满足所需的安全法规。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of a novel compact printed folded dipole antenna for biomedical applications
In this study, a human tissue-implantable compact folded dipole antenna of 19.6 * 2 * 0.254 mm3 operating in the Medical Implant Communication Service (MICS) frequency band (402-405 MHz) is presented. The antenna design and analysis is carried out inside a homogeneous flat phantom with electrical properties equivalent to those of 2/3 human muscle tissue. The dipole antenna, printed on a high-dielectric substrate layer, exhibits a frequency resonance at 402 MHz with a wide 10-dB impedance bandwidth of 105 MHz. The proposed antenna radiates an omnidirectional far-field radiation pattern with a maximum realized gain of -31.2 dB. In addition, the Specific Absorption Rate (SAR) assessment indicates the maximum input power deliverable to the antenna in order to meet the required safety regulations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信