平面,阻抗-公制氮氧化物传感器与NiO传感电极的高温应用

M. Stranzenbach, B. Saruhan
{"title":"平面,阻抗-公制氮氧化物传感器与NiO传感电极的高温应用","authors":"M. Stranzenbach, B. Saruhan","doi":"10.1109/SENSOR.2007.4300297","DOIUrl":null,"url":null,"abstract":"In this study, an innovative type of sensor configuration is used which contains an electrolyte constructed of quasi-single crystalline columns, a porous NiO sensing electrode (SE) and a conductive Pt reference electrode (RE) deposited on the backside. As electrolyte EB-PVD manufactured discs of FYSZ and PYSZ composition were used. Gas sensing characterization of the sensors was carried with typical flue-gas mixtures in various concentrations. Impedance and potential analysis were done at a frequency range of 100 kHz and 0.005 Hz. Sensors with FYSZ electrolyte could be operated at higher temperatures compared to those with PYSZ electrolytes. The highest achieved sensing temperature in this study was 600degC. NO was successfully detected under the presence of 5%vol. O2 at the maximum operating temperature.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Planar, Impedance-Metric NOX Sensor with NiO Sensing Electrode for High Temperature Applications\",\"authors\":\"M. Stranzenbach, B. Saruhan\",\"doi\":\"10.1109/SENSOR.2007.4300297\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, an innovative type of sensor configuration is used which contains an electrolyte constructed of quasi-single crystalline columns, a porous NiO sensing electrode (SE) and a conductive Pt reference electrode (RE) deposited on the backside. As electrolyte EB-PVD manufactured discs of FYSZ and PYSZ composition were used. Gas sensing characterization of the sensors was carried with typical flue-gas mixtures in various concentrations. Impedance and potential analysis were done at a frequency range of 100 kHz and 0.005 Hz. Sensors with FYSZ electrolyte could be operated at higher temperatures compared to those with PYSZ electrolytes. The highest achieved sensing temperature in this study was 600degC. NO was successfully detected under the presence of 5%vol. O2 at the maximum operating temperature.\",\"PeriodicalId\":23295,\"journal\":{\"name\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2007.4300297\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在这项研究中,使用了一种创新类型的传感器配置,它包含由准单晶柱构成的电解质,多孔NiO传感电极(SE)和沉积在背面的导电Pt参比电极(RE)。电解液采用EB-PVD制备的FYSZ和PYSZ组成的圆盘。在不同浓度的典型烟气混合物中对传感器进行了气敏表征。阻抗和电位分析在100 kHz和0.005 Hz的频率范围内进行。与使用PYSZ电解质的传感器相比,使用FYSZ电解质的传感器可以在更高的温度下工作。本研究实现的最高感应温度为600℃。在5%vol的存在下成功检测到NO。O2在最高工作温度下。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Planar, Impedance-Metric NOX Sensor with NiO Sensing Electrode for High Temperature Applications
In this study, an innovative type of sensor configuration is used which contains an electrolyte constructed of quasi-single crystalline columns, a porous NiO sensing electrode (SE) and a conductive Pt reference electrode (RE) deposited on the backside. As electrolyte EB-PVD manufactured discs of FYSZ and PYSZ composition were used. Gas sensing characterization of the sensors was carried with typical flue-gas mixtures in various concentrations. Impedance and potential analysis were done at a frequency range of 100 kHz and 0.005 Hz. Sensors with FYSZ electrolyte could be operated at higher temperatures compared to those with PYSZ electrolytes. The highest achieved sensing temperature in this study was 600degC. NO was successfully detected under the presence of 5%vol. O2 at the maximum operating temperature.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信